HCS03.1E-W0150-A-05-NNNV-AA
Wake Industrial LLC is not an authorized distributor of this product.
MPN: R911331174
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The HCS03.1E-W0150-A-05-NNNV-AA is a control cabinet mounted drive with a rated power of 15 kW and a rated current of 32 A. Manufactured by Bosch Rexroth Indramat as part of the HCS IndraDrive Controllers, it features IP20 protection and operates on an input voltage of 380-480 V AC. Its feedback interface supports multi-encoder inputs.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
HCS IndraDrive Controller model HCS03.1E-W0150-A-05-NNNV-AA provides powerful motion control capable of handling tough applications. It is manufactured by Rexroth Indramat and employs a forced air cooling technique that aids cooling when subjected to a high rate of power effusion.
The HCS03.1E-W0150-A-05-NNNV-AA controller provides continuous rated maximum output current of 150 A. It has an IP20 rated enclosure that offers finger protection IP20 in the factory setting. The input range is 3-phase AC over 400 to 500 V with tolerance between plus 10 and minus 15 percent. It can operate with three phase systems of operation and a fixed phase sequence is not necessary to its correct functioning. It will accommodate input frequency of 50 to 60 Hz that makes it dynamic across various power systems. The rated input current under continuous DC power output conditions is 106 A. It is capable of peak inrush of 5.7 A without decreasing performance during a start up. Its visible power rating when connected in continuous DC output is 72.9 kVA that promotes energy efficient work. It maintains up to 300 watt seconds of power to keep the DC capacitors at short term power stability. The HCS03.1E-W0150-A-05-NNNV-AA controller braking resistors will activate at any internal voltage across the range 820 to 850 V DC. It needs a minimum of 40 microhenries supply inductance to minimize electrical noise and line disturbances. It needs a minimum of 40 microhenries supply inductance to minimize electrical noise and line disturbances.
The HCS03.1E-W0150-A-05-NNNV-AA controller offers a 24 V DC auxiliary output which can be supplied internally from the DC bus or via an external source. It maintains up to 300 watt seconds of power to keep the DC capacitors at short term power stability. The braking resistors will activate at any internal voltage across the range 820 to 850 V DC.
Frequently Asked Questions about HCS03.1E-W0150-A-05-NNNV-AA:
Q: What is the benefit of forced air cooling in the HCS03.1E-W0150-A-05-NNNV-AA controller?
A: Forced air cooling ensures efficient temperature management during high power dissipation, improving the controller's longevity and stability during intense operations.
Q: How does the 106 A DC rated current impact performance?
A: The 106 A DC rated current ensures stable output under continuous power conditions, supporting demanding motion control tasks without compromising performance or reliability.
Q: Why is the 24 V DC auxiliary output useful in the HCS03.1E-W0150-A-05-NNNV-AA controller?
A: The 24 V DC auxiliary output provides flexibility, allowing for external power supply or use of internal DC bus, enhancing system adaptability.
Q: How does the HCS03.1E-W0150-A-05-NNNV-AA controller manage braking resistors?
A: Braking resistors activate within a voltage range of 820 to 850 V DC, ensuring efficient energy dissipation and preventing system overload during braking events.
Q: What does the 5.7 A peak inrush current capability provide?
A: The 5.7 A peak inrush current allows the controller to start up efficiently without performance loss, ensuring smooth power-up even under load.