HCS03.1E-W0150-A-05-NNNN
Wake Industrial LLC is not an authorized distributor of this product.
MPN: R911297851
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The HCS03.1E-W0150-A-05-NNNN, part of Bosch Rexroth Indramat's HCS IndraDrive Controllers, is an IndraDrive HCS03.1E Converter with a power rating of 15 kW. It has a rated current of 33 Amps and operates with input voltages from 380 to 480 V AC. The unit measures 380 x 103 x 380 mm and features internal air cooling for efficiency.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The HCS03.1E-W0150-A-05-NNNN Controller is made for drive control applications in industrial automation. The controller is manufactured by Bosch to support industrial motion systems. This controller provides reliable function under continuous operating loads.
The HCS03.1E-W0150-A-05-NNNN controller uses an internal control voltage of DC 24 V. It does not support motor holding brake through this internal voltage. The external control voltage is DC 24 ±20 percent. When supplying the motor brake, it requires DC 24 ±5 percent. This voltage range helps in accurate brake actuation during runtime. The controller has a power consumption of 25 W. This value excludes the use of control units and brakes. The continuous current is rated at 1 A without control unit or brake. This supports basic system operations in low-load conditions. The mains input voltage ranges from 3 AC 400 to 500 V. It supports a fluctuation of +10 percent and Ð15 percent. The mains frequency lies between 50 to 60 Hz ±2 percent. This provides conformity across international power standards and this frequency and voltage range suits complex installations. The mains input continuous current at PDC continuous load is 106 A which provides sufficient input current to power connected components. The maximum inrush current at peak input voltage is 5.7 A. This rating prevents circuit overload during system startup. It maintains system safety through controlled startup behavior.
The HCS03.1E-W0150-A-05-NNNN controller manages input power accurately during continuous use. It delivers constant voltage across the system during operation. It fits well in automated environments and supports optimized power and drive functions under controlled limits. The structure is made for long-term industrial applications. The current and voltage ratings match demanding drive system requirements. Its design supports advanced machine automation and power handling tasks.
Frequently Asked Questions about HCS03.1E-W0150-A-05-NNNN:
Q: What is the internal control voltage of the HCS03.1E-W0150-A-05-NNNN controller?
A: The HCS03.1E-W0150-A-05-NNNN controller uses an internal control voltage of DC 24 V. This voltage helps regulate the controllers operation but does not support motor holding brakes via this voltage.
Q: What is the continuous current rating of the HCS03.1E-W0150-A-05-NNNN controller?
A: The HCS03.1E-W0150-A-05-NNNN controller has a continuous current rating of 1 A. This supports basic system operations in low-load conditions and is ideal for light industrial automation applications.
Q: What is the mains input voltage range of the HCS03.1E-W0150-A-05-NNNN controller?
A: The HCS03.1E-W0150-A-05-NNNN controller operates with a mains input voltage range of 3 AC 400 to 500 V. This allows it to conform to international power standards, ensuring compatibility with a variety of electrical setups.
Q: What is the power consumption of the HCS03.1E-W0150-A-05-NNNN controller?
A: The HCS03.1E-W0150-A-05-NNNN controller has a power consumption of 25 W, excluding the use of control units and brakes. This ensures efficient energy use in system operations.
Q: How does the HCS03.1E-W0150-A-05-NNNN controller handle inrush current during startup?
A: The HCS03.1E-W0150-A-05-NNNN controller manages inrush current effectively, with a maximum peak of 5.7 A. This helps prevent circuit overload during startup, ensuring smooth and controlled system operation.