The Bosch Rexroth Indramat HCS02.1E-W0054-A-03-NNNV-AA, part of the HCS IndraDrive Controllers series, offers a nominal current rating of 13 Amps and a rated power of 5.4 kW. This panel-mounted drive operates on 380-480V, 3-phase power and includes SERCOS III compatibility. It features an IP20 protection class.

Warranty
Wake Industrial Warranty

Quote Request Form:

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

This HCS02.1E-W0054-A-03-NNNV-AA drive controller from Bosch Rexroth Indramat has to be equipped with an equipment grounding connection before operation. The controller’s dangerous movements because of faulty motor control can take place at any time after operation. This product supports only industrial machinery installation. The device’s housing temperature rises higher than 60 °C when in use. This unit must have no suspended signal lines during operation. Its power cables have to be routed away from the control and signal lines. The controller can be associated with chokes, relays, and other such electronic components only after providing appropriate interference suppression measures.

This product’s connection to the motor is done through its X5 connector. The device can exchange data with other drive controllers using a module bus. This unit’s power cable must be equipped with strain relief within the control cabinet. It has a control voltage of 24 V for the brake of a motor. The controller supports up to 5 m of cable length for the braking resistor if the cable is shielded or twisted. This product must have adequate clearance above and below it inside the control cabinet with its installation. The device has two terminals for the DC bus connection. This unit is to be connected to the left and right screws on the terminal block. It is deployed in handling and mounting systems.

The drive controller may produce an electric shock due to improper use. This product cannot be put into use outside a control cabinet. The device might cause bodily injury if its pressurized lines are handled improperly. This unit’s capacitors take half an hour to discharge fully after a switch-off. Its electrical connection points are not to be touched when the power is on.

Communication Ports
Ethernet, RS232, USB
Control Type
SERCOS III, Multi-Ethernet compatible
Cooling Method
Air (internal)
Current Rating
Nominal 13 A
Device Version
1E
Dimensions (h X W X D)
390 x 110 x 230 mm
Feedback Type Supported
IndraDyn, Resolver, EnDat
Line Voltage
380 - 480 V, 3-phase, 50/60 Hz
Mounting Type
Panel-mounted
Operating Temperature
0 – 40°C (without derating)
Protection Class
IP20
Rated Power
5.4 kW
Weight
Approx. 9 kg
  • HCS021EW0054A03NNNVAA
  • HCS02 1E W0054 A 03 NNNV AA
  • hcs01.1e-w0009-a-02-b-et-ec-nn-l4-nn-fw
  • HCS2.1E-W0054-A-03-NNNV-AA

Frequently Asked Questions about HCS02.1E-W0054-A-03-NNNV-AA:

Q: Which part of the motor does the HCS02.1E-W0054-A-03-NNNV-AA controller control?

A: The HCS02.1E-W0054-A-03-NNNV-AA controller controls the holding brake of the motor.

Q: How should the power connection of the HCS02.1E-W0054-A-03-NNNV-AA controller be isolated?

A: The power connection of the HCS02.1E-W0054-A-03-NNNV-AA controller should be isolated by an emergency stop circuit.

Q: How is the cooling of the HCS02.1E-W0054-A-03-NNNV-AA controller done?

A: The cooling of the HCS02.1E-W0054-A-03-NNNV-AA controller is done by internal air circulation through an integrated blower.

Q: What power supply does the HCS02.1E-W0054-A-03-NNNV-AA controller have?

A: The HCS02.1E-W0054-A-03-NNNV-AA controller has an integrated 24 V power supply.

Q: What type of connector is the X9 connector of the HCS02.1E-W0054-A-03-NNNV-AA controller?

A: The X9 connector of the HCS02.1E-W0054-A-03-NNNV-AA controller is a screw terminal block with two poles.