The Bosch Rexroth Indramat HCS02.1E-W0054-A-03-NNNN-AA is part of the HCS IndraDrive Controllers, featuring internal fan cooling and a rated output current of 54 Amps. It operates at 3 x AC 400 V (+/- 10%) and weighs approximately 17 kg. The controller has integrated Safe Torque Off (STO) for enhanced safety.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
This HCS02.1E-W0054-A-03-NNNN-AA drive controller delivered by Bosch Rexroth Indramat supports mounting only in its upright position. The controller supports master-drive communication using parameters. This product’s operating data are mapped to their parameters. The device-related parameter values and firmware are contained in its controller memory. This unit’s parameter values are stored through either its commissioning tool or comfort control panel. Its parameter values are protected by three hierarchically different passwords. The controller’s control section is smaller than the power section.
This product’s power section is connected to its related motor. The device’s endangered components must be stored in conductive packaging. This unit releases analog signals that must be transmitted through shielded lines. It should be free of fault or damage when it is mounted. The controller’s use is supported only after understanding its documentation. This product controls as well as monitors the operation of the associated motor. The device-associated errors are classified under eight error classes. This unit’s operating mode determines which and how the command values will be processed. Its control panel displays AF on activation of an operating mode.
The controller executes many monitoring functions based on the parameter settings and the active operating mode. This product’s error memory stores the diagnostic message numbers of the last 50 errors. The device’s control section can be configured according to the requirements. This unit can operate with a third-party motor that meets the conditions specified. Its firmware supports multiple operating modes such as drive-internal interpolation, positioning block mode, and drive-controlled positioning. The drive controller’s connection should be established with the manufacturer’s cables and also allows operation with only the manufacturer-approved parts and components.
Frequently Asked Questions about HCS02.1E-W0054-A-03-NNNN-AA:
Q: What error messages are not stored in the error memory of the HCS02.1E-W0054-A-03-NNNN-AA controller?
A: Errors caused by a shutdown of the control voltage are not stored in the error memory of the HCS02.1E-W0054-A-03-NNNN-AA controller.
Q: What are the probe inputs of the control section of the HCS02.1E-W0054-A-03-NNNN-AA controller used for?
A: The probe inputs of the control section of the HCS02.1E-W0054-A-03-NNNN-AA controller are used as bounce-free switches.
Q: Can the HCS02.1E-W0054-A-03-NNNN-AA controller be modified by the user?
A: No, the HCS02.1E-W0054-A-03-NNNN-AA controller cannot be modified by the user and must be retained in the original state.
Q: What regulations must be followed when installing the HCS02.1E-W0054-A-03-NNNN-AA controller?
A: The general installation and safety regulations must be followed when installing the HCS02.1E-W0054-A-03-NNNN-AA controller.
Q: What is the leakage current of the HCS02.1E-W0054-A-03-NNNN-AA controller?
A: The leakage current of the HCS02.1E-W0054-A-03-NNNN-AA controller is more than 3.5 mA.