HCS02.1E-W0028-S-03-NNNN
Wake Industrial LLC is not an authorized distributor of this product.
MPN: R911323535
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
-
Available
The HCS02.1E-W0028-S-03-NNNN IndraDrive controller supports a rated output current of 28 amps, operates with line voltages of 3-phase 200 to 500 V AC, uses air cooling via an internal fan, and weighs approximately 8 kg. Part of the HCS IndraDrive Controllers by Bosch Rexroth Indramat, it features IP20 protection.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
Crafted by Bosch Rexroth Indramat, the HCS02.1E-W0028-S-03-NNNN drive controller is an IndraDrive C controller. This controller has a data memory that contains its firmware and specific parameter values. The product is installed inside a control cabinet in the vertical position. This device allows its parameter values to be protected by using a password. The unit’s complex functions are activated and controlled through various commands. It supports three kinds of commands. This controller displays warnings and errors as part of its fault diagnostics.
The product’s error messages can be cleared by pressing the Esc key on its control panel. This device comes with a control section and a power section. The unit’s power section has a 300 mm width. It is compatible with the manufacturer’s MHD, MKD, MKE, MSK, MAL, and SF motors. This controller establishes master communication by using a PROFIBUS interface. The product’s surface has a very high temperature during and soon after use. This device’s firmware offers support for various operating modes. The unit is in a drive system that complies with EC low voltage and machine directives. Its original state must be retained without structural or construction changes.
This controller has no underwater operation support. The product’s improper use can result in unfavorable situations. This device is installable only in machinery for industrial use. The unit triggers high voltage because of incorrect use. It should not be utilized without its grounding connection. This drive controller’s dangerous movements are a result of faulty motor control. The product has separate type plates for each of its sections. This device features a 3K3 climatic category as per IEC 721 specifications. The unit has digital inputs and outputs. It must be distanced from an adjacent drive controller by at least 5 mm.
Frequently Asked Questions about HCS02.1E-W0028-S-03-NNNN:
Q: What is the protection class of the HCS02.1E-W0028-S-03-NNNN controller?
A: The protection class of the HCS02.1E-W0028-S-03-NNNN controller is IP 20.
Q: What are the two types of data memory of the HCS02.1E-W0028-S-03-NNNN controller?
A: The two types of data memory of the HCS02.1E-W0028-S-03-NNNN controller are volatile and non-volatile data memories.
Q: What are the three types of passwords supported by the HCS02.1E-W0028-S-03-NNNN controller?
A: The three types of passwords supported by the HCS02.1E-W0028-S-03-NNNN controller are customer, control, and master passwords.
Q: How are the functions of the HCS02.1E-W0028-S-03-NNNN controller activated or deactivated?
A: The functions of the HCS02.1E-W0028-S-03-NNNN controller are activated or deactivated using the monitoring commands.
Q: What kind of warnings cause an automatic shutdown of the HCS02.1E-W0028-S-03-NNNN controller?
A: Fatal warnings cause an automatic shutdown of the HCS02.1E-W0028-S-03-NNNN controller.