HCS02.1E-W0012-A-03-NNNN-AA

Ask for Availability

Preparing your secure checkout page...

The Bosch Rexroth Indramat HCS02.1E-W0012-A-03-NNNN-AA controller, part of the HCS IndraDrive Controllers Series, features internal fan cooling and fits neatly into a control cabinet. It operates on a 24 V DC control voltage, with an input range of 3x AC 230-480 V and 50/60 Hz frequency. The unit measures 105mm x 355mm x 263mm.

Warranty
Wake Industrial Warranty

Quote Request Form:

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The HCS02.1E-W0012-A-03-NNNN-AA is manufactured by Bosch Rexroth that joins the top-selling HCS IndraDrive Controllers series. As a compact drive controller, it features input voltage range of 3 x AC 230...480 V (-15 %...+10 %) that accommodates mains variations which ensures stable operation under fluctuating supply conditions. A 50/60 Hz input frequency tolerance of ~2 % matches global utility standards which maintains consistent drive performance. Rated current of 12 A delivers sufficient drive capacity which supports medium-power single-axis applications.

A 24 V DC control voltage tolerance of -15 %...+20 % stabilizes logic circuits, thus avoids undervoltage faults. Continuous output current of 12 A for this module at a 4 kHz switching frequency maintains steady motor torque which preserves motion smoothness. Output power varies according to connected motor type which provides flexibility for synchronous or asynchronous drives. Moreover, the process of internal fan cooling removes heat via an integrated blower which prevents thermal overload without external chillers. IP rating of IP20 blocks solid objects above 12 mm, thereby safeguards live components in control cabinets. A control cabinet mounting form factor ensures secure installation within electrical enclosures which minimizes wiring exposure. Dimensions of around 105 mm x 355 mm x 263 mm deliver a narrow footprint which increases space efficiency.

The base version of HCS02.1E-W0012-A-03-NNNN-AA controller lacks a communication interface which reserves the control unit slot for option cards. Design version 1 aligns hardware revisions with firmware updates that simplifies lifecycle management. Also, a single control unit slot accepts fieldbus or scalable interface cards to extend connectivity options. For this variant, the power ranges from 1.5 kW to 11 kW covers typical industrial motor requirements. Operating temperature up to 40 degrees C secures reliable function in standard industrial environments, hence avoids derating under moderate heat.

Communication Interface
None (base version, option cards available)
Continuous Output Current
12 A (at 4 kHz switching frequency)
Control Voltage
24 V DC (-15%...+20%)
Cooling Method
Internal fan
Input Frequency
50/60 Hz (~2%)
Input Voltage
3 x AC 230...480 V (-15%...+10%)
Mounting
Control cabinet
Output Power
Varies based on connected motor (Synchronous/Asynchronous)
Protection Class
IP20
Rated Current
12 A
Size (w X H X D)
Approx. 105 mm x 355 mm x 263 mm
  • HCS042EW1540
  • HCS04 2E W1540
  • hcs04.2e-w1540
  • HCS2.1E-W0012-A-03-NNNN-AA

Frequently Asked Questions about HCS02.1E-W0012-A-03-NNNN-AA:

Q: How does input frequency tolerance benefit the HCS02.1E-W0012-A-03-NNNN-AA?

A: A 50/60 Hz frequency window of ~2 % matches global utility standards which maintains timing integrity for motor control loops without frequency-induced drift.

Q: Why is the rated current specification important for the HCS02.1E-W0012-A-03-NNNN-AA?

A: With a rated current of 12 A, it supplies the inverter section with adequate power which ensures robust performance for single-axis automation without overloading electrical circuits.

Q: How does control voltage tolerance affect the HCS02.1E-W0012-A-03-NNNN-AA's logic circuits?

A: A 24 V DC range of -15 %...+20 % preserves stable logic operation which prevents undervoltage shutdowns and ensures reliable drive readiness signaling.

Q: What role does continuous output current play in the HCS02.1E-W0012-A-03-NNNN-AA?

A: Continuous output current of 12 A at 4 kHz switching frequency maintains motor torque delivery which promotes smooth acceleration and deceleration cycles.

Q: How does output power variability serve the HCS02.1E-W0012-A-03-NNNN-AA?

A: Output power varies with connected motor type provides flexibility for both synchronous and asynchronous applications, thus allows one controller to suit multiple drive profiles.


Internal Product Review

  • ‘‘Being a member of the Indramat's famous HCS IndraDrive Controllers, the module HCS02.1E-W0012-A-03-NNNN-AA allows internal fan for cooling to sustain continuous 12 A output without external chillers. Also, its 24 V DC control voltage tolerance prevents undervoltage interruptions. This pairing ensures uninterrupted drive performance in demanding automation tasks.’’

Motion Industries logo