4.95 based on 202 reviews

🙶 Wake was very helpful in getting us a servo motor and drive for our tube mill line. This was the first tim... 🙷

HCS01.1E-W0054-A-03-B-ET-EC-NN-NN-NN-AW Bosch Rexroth Indramat

MPN: R911400012

No Tariffs On US Orders
  • Rated 4.4 (49 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
Ask for Availability

Preparing your secure checkout page...

The Bosch Rexroth Indramat HCS01.1E-W0054-A-03-B-ET-EC-NN-NN-NN-AW is part of the HCS IndraDrive Controllers series and is a drive controller with a peak current of 54 Amps. It has a MultiEthernet communication interface, uses internal air cooling through an integrated blower, and features an IP20 rating. This controller operates at a mains voltage of 3 x AC 200 to 500 Volts and includes an encoder interface supporting IndraDyn Hiperface and EnDat 2.1/2.2.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The HCS01.1E-W0054-A-03-B-ET-EC-NN-NN-NN-AW is a compact servo drive controller from Bosch Rexroth Indramat in the HCS IndraDrive Controllers series. The unit forms the power and communication link between an automation system and synchronous or asynchronous motors, processing command data and modulating current for precise speed, torque, and position control. By integrating supply, inverter, and diagnostic functions in one module, it helps simplify cabinet layouts in assembly cells, packaging machinery, and material-handling lines that require responsive axis performance. This arrangement also lets the drive report status information to the higher-level control while managing motor response at the axis.

Designed for universal power grids, the controller accepts 3 x AC 200...500 V with a ±10% tolerance, so one unit can be used on low- or high-voltage installations without a transformer. During short acceleration bursts, it can deliver a peak current of 54 A, giving extra headroom for high-inertia axes. The housing has an IP20 protection class, so live parts must be enclosed in a cabinet. Thermal management uses internal air cooling through an integrated blower, and real-time networking is handled by the MultiEthernet interface, which supports PROFINET, EtherNet/IP, EtherCAT, and SERCOS on one port. This wide input range helps standardize installations across facilities that use different mains voltages.

Axis logic runs in the BASIC control section, paired with the power stage referenced by option code B. The unit is Design Version 1. The supply type is Infeeding / Feeded, which supports regenerative braking and shared power between drives over a common DC bus. Position feedback is accepted through a single encoder port that supports IndraDyn Hiperface/EnDat 2.1/2.2. The encoder interface allows direct connection to common motor feedback systems used on this platform. A second feedback channel and a safety interface are not fitted.

Communication Interface
MultiEthernet
Control Section Design Type
BASIC
Cooling Method
Air, internal (through integrated blower)
Design Version
1
Device Peak Current
54 A
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Interface 2 Type
Not equipped
IP Rating
IP20
Line Series
HCS01
Mains Voltage
3 x AC 200...500 V ±10%
Other Design Features
None
Pairing Note
Paired with Control Section Design 'BASIC' (B)
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
Safety Interface
Not equipped
  • HCS011EW0054A03BETECNNNNNNAW
  • HCS01 1E W0054 A 03 B ET EC NN NN NN AW
  • hcs01.1e-w0054-a-03-a-cc-ec-em-l3-nn-fw
  • HCS1.1E-W0054-A-03-B-ET-EC-NN-NN-NN-AW

Frequently Asked Questions about HCS01.1E-W0054-A-03-B-ET-EC-NN-NN-NN-AW:

Q: What communication interface is available on the HCS01.1E-W0054-A-03-B-ET-EC-NN-NN-NN-AW controller?

A: This model supports MultiEthernet communication for versatile network integration.

Q: What is the device peak current rating for the HCS01.1E-W0054-A-03-B-ET-EC-NN-NN-NN-AW?

A: The drive controller can handle a device peak current of 54 A, which enables it to support demanding load conditions.

Q: How is the HCS01.1E-W0054-A-03-B-ET-EC-NN-NN-NN-AW cooled?

A: Cooling is provided by an internal blower, allowing for efficient air cooling within the device housing.

Q: What is the acceptable mains voltage range for the HCS01.1E-W0054-A-03-B-ET-EC-NN-NN-NN-AW?

A: This controller is suitable for use on 3-phase AC mains voltages ranging from 200 to 500 V with a tolerance of ±10%.

Q: What type of encoder interface is offered on the HCS01.1E-W0054-A-03-B-ET-EC-NN-NN-NN-AW controller?

A: The encoder interface supports IndraDyn Hiperface and EnDat 2.1/2.2 for feedback connectivity.


Internal Product Review

  • ‘‘The HCS01.1E-W0054-A-03-B-ET-EC-NN-NN-NN-AW is an HCS Drive Controller with MultiEthernet communication and a BASIC control section. Internal air cooling through an integrated blower and IP20 protection support dependable cabinet installation in automated machinery. A 54 A peak current rating with 3 x AC 200...500 V mains input makes this unit a strong choice for responsive IndraDrive motion control.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo