HCS01.1E-W0054-A-03-B-ET-EC-NN-L4-NN-PW Bosch Rexroth Indramat
MPN: R911173170
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The Bosch Rexroth Indramat HCS01.1E-W0054-A-03-B-ET-EC-NN-L4-NN-PW is part of the HCS IndraDrive Controllers series and features a MultiEthernet communication interface. This HCS drive controller has an integrated blower for internal air cooling and a peak device current of 54 Amps. It supports encoder interfaces like IndraDyn Hiperface and EnDat 2.1/2.2 and is rated at IP20 protection.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The HCS01.1E-W0054-A-03-B-ET-EC-NN-L4-NN-PW is a single-axis HCS Drive Controller produced by Bosch Rexroth Indramat for the HCS IndraDrive Controllers series. It combines a regulated power stage with onboard logic so that motors can be started, stopped, and monitored from the same housing. In automated cells, this controller manages torque, speed, and position loops while exchanging diagnostic data with higher-level PLCs over its real-time network links.
Electrical energy is accepted from 3 × AC 200–500 V ±10%, and this wide mains span lets one hardware type serve both 230 V and 480 V plant zones. The power stage can supply up to 54 A of peak current, allowing short acceleration bursts without saturation. Heat is removed by internal air cooling through an integrated blower, so cabinet air remains the cooling medium and no external heat sink is required. All field communication is handled through a MultiEthernet interface that supports several Ethernet-based protocols without extra option cards. The enclosure is rated IP20, indicating finger-safe electrical parts but requiring installation inside a protected control cabinet. Interface 2 is left unequipped, and the unit is identified as design version 1 of the HCS01 line.
The controller uses a BASIC control section matched to the power stage. Position feedback is processed through an encoder port for IndraDyn Hiperface and EnDat 2.1/2.2. Integrated functional safety is provided by STO and SBC, letting the axis meet Category 3 stop requirements without external relays. Power can be shared along a DC bus because the converter supports infeeding and fed operation, which reduces the need for dedicated supply modules. The line designation HCS01, the absence of additional design features, and unequipped auxiliary interfaces keep the configuration straightforward while still covering common motion tasks.
Frequently Asked Questions about HCS01.1E-W0054-A-03-B-ET-EC-NN-L4-NN-PW:
Q: What communication interface does the HCS01.1E-W0054-A-03-B-ET-EC-NN-L4-NN-PW provide?
A: The HCS01.1E-W0054-A-03-B-ET-EC-NN-L4-NN-PW supports MultiEthernet for flexible network integration.
Q: What is the maximum peak current rating of the HCS01.1E-W0054-A-03-B-ET-EC-NN-L4-NN-PW?
A: The peak device current is 54 A for the HCS01.1E-W0054-A-03-B-ET-EC-NN-L4-NN-PW.
Q: How is the HCS01.1E-W0054-A-03-B-ET-EC-NN-L4-NN-PW cooled?
A: This drive features internal air cooling accomplished by an integrated blower.
Q: What safety options are available on the HCS01.1E-W0054-A-03-B-ET-EC-NN-L4-NN-PW?
A: The safety interface includes both Safe Torque Off (STO) and Safe Brake Control (SBC).
Q: What is the mains voltage requirement for the HCS01.1E-W0054-A-03-B-ET-EC-NN-L4-NN-PW?
A: The controller operates with a mains voltage range of 3 x AC 200 to 500 V ±10%.