4.95 based on 202 reviews

🙶 Easy to navigate website and quick responses from support. Additionally, pretty fast shipping. Our mainte... 🙷

HCS01.1E-W0054-A-03-B-ET-EC-EP-SB-NN-FW Bosch Rexroth Indramat

MPN: R911390036

No Tariffs On US Orders
  • Rated 4.6 (71 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
Ask for Availability

Current response time:
4 Minutes 24 Seconds

Preparing your secure checkout page...

The Bosch Rexroth Indramat HCS01.1E-W0054-A-03-B-ET-EC-EP-SB-NN-FW is part of the HCS IndraDrive Controllers series. This drive controller features a MultiEthernet communication interface and an internal air cooling system with an integrated blower. It offers a device peak current of 54 amps and has an IP20 protection rating, operating at a mains voltage of 3 x AC 200 to 500 volts.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The HCS01.1E-W0054-A-03-B-ET-EC-EP-SB-NN-FW is a compact drive controller manufactured by Bosch Rexroth Indramat within the HCS IndraDrive Controllers series. It serves as an intelligent power stage that converts three-phase mains energy into regulated output for servo axes while exchanging real-time status data with higher-level PLCs. By combining control and power electronics in one enclosure, the unit supports coordinated positioning, speed, and torque control in applications such as pick-and-place gantries, conveyor sections, and packaging equipment.

This model communicates over MultiEthernet, allowing integration with industrial Ethernet networks through the available communication platform. Its input accepts 3 × AC 200–500 V ±10%, so the drive can operate on common low- and medium-voltage supply systems. Cooling is provided by an internal air blower, which circulates cabinet air to remove heat from the power electronics. The housing has an IP20 rating, which provides finger-safe protection against solid objects while leaving the enclosure open to ventilation. Feedback is handled through an IndraDyn Hiperface/EnDat 2.1/2.2 encoder interface, giving the controller direct access to motor position data for closed-loop operation. During acceleration or rapid load changes, the inverter can deliver up to 54 A of peak output current to support short-term torque demand.

The control section uses BASIC functionality, providing standard motion functions and parameter sets for typical axis applications. The DC link uses a common DC bus supply, allowing several drives in the system to share regenerated energy through the same bus. The unit is identified as design version 1, which indicates the product revision used for this controller. This arrangement supports multi-axis installations where compact layout, shared power distribution, and integrated feedback handling are required.

Communication Interface
MultiEthernet
Control Section Design Type
BASIC
Cooling Method
Air, internal (through integrated blower)
Design Version
1
Device Peak Current
54 A
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
IP Rating
IP20
Line Series
HCS01
Mains Voltage
3 x AC 200...500 V ±10%
Other Design Features
None
Pairing Note
Paired with Control Section Design 'BASIC' (B)
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
  • HCS011EW0054A03BETECEPSBNNFW
  • HCS01 1E W0054 A 03 B ET EC EP SB NN FW
  • hcs01.1e-w0028_a-03-b-et-ec-nn-nn-nn-fw
  • HCS1.1E-W0054-A-03-B-ET-EC-EP-SB-NN-FW

Frequently Asked Questions about HCS01.1E-W0054-A-03-B-ET-EC-EP-SB-NN-FW:

Q: Which communication interface is provided on the HCS01.1E-W0054-A-03-B-ET-EC-EP-SB-NN-FW controller?

A: The HCS01.1E-W0054-A-03-B-ET-EC-EP-SB-NN-FW supports MultiEthernet communication interfaces.

Q: What is the peak current rating of the HCS01.1E-W0054-A-03-B-ET-EC-EP-SB-NN-FW drive controller?

A: This model offers a device peak current of 54 A, enabling it to handle demanding operational loads.

Q: What cooling method does the HCS01.1E-W0054-A-03-B-ET-EC-EP-SB-NN-FW utilize?

A: Cooling for this drive controller is achieved through internal air via an integrated blower.

Q: What is the supported mains voltage range for the HCS01.1E-W0054-A-03-B-ET-EC-EP-SB-NN-FW?

A: The controller operates with a mains voltage in the range of 3 x AC 200 to 500 V, plus or minus 10%.

Q: Which encoder interfaces are available on the HCS01.1E-W0054-A-03-B-ET-EC-EP-SB-NN-FW controller?

A: This unit features an encoder interface compatible with IndraDyn Hiperface and EnDat 2.1/2.2 standards.


Internal Product Review

  • ‘‘The HCS01.1E-W0054-A-03-B-ET-EC-EP-SB-NN-FW is an HCS drive controller with MultiEthernet communication. Internal air cooling through an integrated blower and IP20 protection support dependable cabinet installation. Operation on 3 x AC 200...500 V ±10% with 54 A peak current makes this unit a strong choice for demanding drive applications.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo