HCS01.1E-W0054-A-03-B-ET-EC-EP-NN-NN-FW Bosch Rexroth Indramat
MPN: R911396749
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The Bosch Rexroth Indramat HCS01.1E-W0054-A-03-B-ET-EC-EP-NN-NN-FW is a drive controller from the HCS IndraDrive Controllers series. It features a MultiEthernet communication interface and supports encoder interfaces such as IndraDyn Hiperface and EnDat 2.1/2.2. The controller has a device peak current of 54 Amps and uses internal air cooling through an integrated blower.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The HCS01.1E-W0054-A-03-B-ET-EC-EP-NN-NN-FW is an AC drive controller built by Bosch Rexroth Indramat for the HCS IndraDrive Controllers series. As a compact drive unit, it coordinates torque, speed, and position loops for synchronous or induction motors in modular automation cells such as packaging lines and pick-and-place axes. The controller integrates its power stage and control electronics in one enclosure, allowing machine builders to add motion control without a separate external drive. It fits into the HCS01 line size and is used where single-axis regulation up to medium power is required.
The communication backplane supports MultiEthernet, allowing the device to switch among Sercos III, EtherNet/IP, PROFINET, and TCP/IP without hardware changes. Its power section accepts a three-phase supply of 3 x AC 200…500 V ±10%, allowing use on low- or high-voltage plant mains with a single variant. During acceleration, the inverter can deliver a device peak current of 54 A, allowing high short-term torque from the paired motor. The housing carries an IP20 rating, so it must be mounted inside a protective cabinet but remains accessible for front wiring. Feedback data arrive over the primary encoder port, which supports IndraDyn, Hiperface, or EnDat 2.1/2.2 encoders for high-resolution position control.
The power module is paired with a BASIC control section, which provides standard motion functions without integrated safety I/O. Heat is removed by internal air cooling through an integrated blower, so no external ducting is necessary and cabinet temperature rise remains predictable. The DC link can operate in an infeeding or feeding topology, so the unit can either supply or absorb regenerative energy according to machine duty. The unit is Version 1. The safety interface is unequipped, so risk-reduction functions must be handled by upstream controls.
Frequently Asked Questions about HCS01.1E-W0054-A-03-B-ET-EC-EP-NN-NN-FW:
Q: What communication interface is available on the HCS01.1E-W0054-A-03-B-ET-EC-EP-NN-NN-FW controller?
A: The HCS01.1E-W0054-A-03-B-ET-EC-EP-NN-NN-FW features a MultiEthernet communication interface for flexible network connectivity.
Q: What is the device peak current for the HCS01.1E-W0054-A-03-B-ET-EC-EP-NN-NN-FW?
A: This drive controller has a peak current rating of 54 A, supporting demanding automation tasks.
Q: How is the HCS01.1E-W0054-A-03-B-ET-EC-EP-NN-NN-FW cooled during operation?
A: Cooling is provided by an internal integrated blower, ensuring efficient thermal management without external cooling.
Q: What mains voltage range does the HCS01.1E-W0054-A-03-B-ET-EC-EP-NN-NN-FW support?
A: This model operates with a mains voltage range of 3 x AC 200...500 V ±10% for wide compatibility with industrial power systems.
Q: Is a safety interface included with the HCS01.1E-W0054-A-03-B-ET-EC-EP-NN-NN-FW?
A: The safety interface is not equipped on this controller, so extra safety modules may be required in some applications.