4.95 based on 202 reviews

🙶 Easy to navigate website and quick responses from support. Additionally, pretty fast shipping. Our mainte... 🙷

HCS01.1E-W0054-A-03-B-ET-EC-EM-SB-NN-FW Bosch Rexroth Indramat

MPN: R911383139

No Tariffs On US Orders
  • Rated 4.4 (36 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
Ask for Availability

Preparing your secure checkout page...

The Bosch Rexroth Indramat HCS01.1E-W0054-A-03-B-ET-EC-EM-SB-NN-FW is a drive controller from the HCS IndraDrive Controllers series. It features a MultiEthernet communication interface, supports a device peak current of 54 Amps, and has IP20 protection. The controller uses an internal air cooling method with an integrated blower and is designed to work with IndraDyn Hiperface or EnDat encoder interfaces.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The HCS01.1E-W0054-A-03-B-ET-EC-EM-SB-NN-FW belongs to the HCS IndraDrive Controllers series from Bosch Rexroth Indramat. As an HCS drive controller, it supplies regulated power and motion commands to connected servo or induction motors in automated machinery, material-handling lines, and similar production equipment. The unit integrates the power section and a replaceable control section so that a single package can execute positioning, speed, and torque loops under a central PLC or fieldbus host during coordinated machine operation.

Networked communication is provided through the MultiEthernet interface, allowing EtherNet/IP, PROFINET, or EtherCAT protocols to be selected in software without extra hardware. The control section installed in this build is the BASIC variant, identified by the B code and paired at the factory for standard motion tasks. Thermal management relies on internal air cooling delivered by an integrated blower, and this method removes heat without external ducts or liquid circuits. During dynamic acceleration, the power stage can supply up to 54 A of peak output current, supporting short-term overload demand at the motor. The enclosure is rated IP20, so the controller must be mounted inside a closed electrical cabinet.

Main power is accepted from 3 × AC 200–500 V lines with a ±10% tolerance, giving flexibility for a wide range of plant supply voltages. Feedback wiring can connect to the Encoder IndraDyn Hiperface/EnDat 2.1/2.2 port, and downstream devices can use the built-in encoder emulation output for follower applications that require replicated position or speed signals. The power supply section supports infeeding and fed operation, so the controller can return braking energy to a shared DC bus or draw energy from that bus when configured as a follower.

Communication Interface
MultiEthernet
Control Section Design Type
BASIC
Cooling Method
Air, internal (through integrated blower)
Design Version
1
Device Peak Current
54 A
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Interface 2 Type
Encoder emulation
IP Rating
IP20
Line Series
HCS01
Mains Voltage
3 x AC 200...500 V ±10%
Other Design Features
None
Pairing Note
Paired with Control Section Design 'BASIC' (B)
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
  • HCS011EW0054A03BETECEMSBNNFW
  • HCS01 1E W0054 A 03 B ET EC EM SB NN FW
  • hcs01.1e-w0028-a-03-e-s3-ec-nn-l4-aa-fw
  • HCS1.1E-W0054-A-03-B-ET-EC-EM-SB-NN-FW

Frequently Asked Questions about HCS01.1E-W0054-A-03-B-ET-EC-EM-SB-NN-FW:

Q: What type of communication interface is equipped on the HCS01.1E-W0054-A-03-B-ET-EC-EM-SB-NN-FW controller?

A: The HCS01.1E-W0054-A-03-B-ET-EC-EM-SB-NN-FW supports MultiEthernet communication for versatile network integration.

Q: What is the peak current capacity of the HCS01.1E-W0054-A-03-B-ET-EC-EM-SB-NN-FW?

A: This device can deliver a peak current of up to 54 A for demanding drive applications.

Q: How is the HCS01.1E-W0054-A-03-B-ET-EC-EM-SB-NN-FW cooled?

A: Cooling is managed internally by an integrated blower that provides air circulation within the unit.

Q: What is the mains voltage range for this IndraDrive controller?

A: The HCS01.1E-W0054-A-03-B-ET-EC-EM-SB-NN-FW operates with a mains voltage supply of 3 x AC 200...500 V ±10%.

Q: What is the IP rating of the HCS01.1E-W0054-A-03-B-ET-EC-EM-SB-NN-FW controller?

A: It is rated with an IP20 protection level, which means it is protected against solid objects greater than 12.5 mm.


Internal Product Review

  • ‘‘The HCS01.1E-W0054-A-03-B-ET-EC-EM-SB-NN-FW is an HCS drive controller with MultiEthernet communication. Internal air cooling through an integrated blower supports effective thermal management, and IP20 protection fits well in controlled cabinet installations. A 54 A peak current and 3 x AC 200 to 500 V mains range make the controller a strong choice for demanding servo drive applications.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo