HCS01.1E-W0054-A-03-B-ET-EC-EM-L4-NN-FW Bosch Rexroth Indramat

MPN: R911337363

No Tariffs On US Orders
  • Rated 4.4 (57 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
Ask for Availability

Preparing your secure checkout page...

The Bosch Rexroth Indramat HCS01.1E-W0054-A-03-B-ET-EC-EM-L4-NN-FW is a drive controller from the HCS IndraDrive Controllers series. It supports MultiEthernet communication and operates at a device peak current of 54 Amps with air cooling through an integrated blower. The controller features STO and SBC safety interfaces and an IP20 rating.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The HCS01.1E-W0054-A-03-B-ET-EC-EM-L4-NN-FW drive controller is manufactured by Bosch Rexroth Indramat as part of the HCS IndraDrive Controllers series. Assigned to the HCS01 line, this unit serves as the power and control interface between a three-phase mains supply and servo or induction motors. It supplies regulated current and receives feedback to maintain commanded motion profiles in compact multi-axis assemblies used on assembly lines and process equipment. The housing combines the control electronics, power stage, and diagnostic functions in a single unit, which helps reduce panel space in tightly arranged machine layouts.

Field-level data exchange is routed through the MultiEthernet port, giving the controller direct access to several industrial Ethernet protocols without add-on cards. Its power stage connects to a 3 x AC 200…500 V ±10% supply and can deliver up to 54 A of peak output, allowing the attached motor to receive high acceleration current when required. Heat is removed by internal air cooling through an integrated blower, so no external ductwork is required for nominal loading. The enclosure has an IP20 protection class and is intended for installation in industrial cabinets, where protection against accidental contact with larger solid objects is required.

Safety is handled by STO and SBC, enabling drive-level torque shutdown and brake control functions without additional contactors. Position feedback enters through the IndraDyn Hiperface/EnDat 2.1/2.2 encoder input, while legacy controls can obtain simulated pulses through encoder emulation. This arrangement supports both modern servo feedback interfaces and pulse-style outputs for connected control hardware. The power section supports infeeding and fed operation, so it can return regenerated energy to the DC bus or accept energy from an upstream supply module. The controller uses the BASIC control section with design version 1 for this configuration.

Communication Interface
MultiEthernet
Control Section Design Type
BASIC
Cooling Method
Air, internal (through integrated blower)
Design Version
1
Device Peak Current
54 A
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Interface 2 Type
Encoder emulation
IP Rating
IP20
Line Series
HCS01
Mains Voltage
3 x AC 200...500 V ±10%
Other Design Features
None
Pairing Note
Paired with Control Section Design 'BASIC' (B)
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
Safety Interface
STO (Safe Torque Off) and SBC (Safe Brake Control)
  • HCS011EW0054A03BETECEML4NNFW
  • HCS01 1E W0054 A 03 B ET EC EM L4 NN FW
  • hcs01.1e-w0028-a-03-e-s3-ec-ep-l3-nn-fw
  • HCS1.1E-W0054-A-03-B-ET-EC-EM-L4-NN-FW

Frequently Asked Questions about HCS01.1E-W0054-A-03-B-ET-EC-EM-L4-NN-FW:

Q: What type of communication interface does the HCS01.1E-W0054-A-03-B-ET-EC-EM-L4-NN-FW controller use?

A: This controller supports MultiEthernet communication, which provides compatibility with multiple Ethernet-based network protocols.

Q: What is the device peak current rating for the HCS01.1E-W0054-A-03-B-ET-EC-EM-L4-NN-FW?

A: The HCS01.1E-W0054-A-03-B-ET-EC-EM-L4-NN-FW offers a device peak current of 54 A for high-performance drive applications.

Q: How is the HCS01.1E-W0054-A-03-B-ET-EC-EM-L4-NN-FW cooled during operation?

A: Cooling for this controller is handled internally via an integrated air blower, ensuring effective thermal management.

Q: What mains voltage range does the HCS01.1E-W0054-A-03-B-ET-EC-EM-L4-NN-FW controller support?

A: The mains voltage supported by this drive is 3 x AC 200 to 500 V with a tolerance of plus or minus 10%.

Q: What safety features are included on the HCS01.1E-W0054-A-03-B-ET-EC-EM-L4-NN-FW drive controller?

A: This model features both STO (Safe Torque Off) and SBC (Safe Brake Control) as safety interfaces.


Internal Product Review

  • ‘‘The HCS01.1E-W0054-A-03-B-ET-EC-EM-L4-NN-FW is an HCS drive controller configured with a BASIC control section. Internal blower cooling supports stable thermal performance, and the 3 x AC 200 to 500 V mains range suits demanding industrial power environments. MultiEthernet connectivity and 54 A peak current make this controller an excellent choice for responsive, networked motion control.’’