The Bosch Rexroth Indramat HCS01.1E-W0054-A-03-B-ET-EC-EC-SB-NN-FW is a drive controller from the HCS IndraDrive Controllers series. It features a MultiEthernet communication interface and supports mains voltages of 3-phase AC 200 to 500 V. The controller uses internal air cooling with an integrated blower and provides a device peak current of 54 Amps.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The HCS01.1E-W0054-A-03-B-ET-EC-EC-SB-NN-FW is a drive controller produced by Bosch Rexroth Indramat for the HCS IndraDrive Controllers series. Installed between the plant mains and a servo or spindle motor, this unit regulates current and velocity loops while exchanging motion commands with higher-level PLCs. Within an automation cell, it supplies the power stage, interprets encoder feedback, and coordinates dynamic profiles for pick-and-place, packaging, or machining axes. This arrangement lets the drive react quickly to motor feedback while the machine controller manages overall axis coordination.

Its network stack is configured for MultiEthernet, allowing the same hardware to communicate over EtherNet/IP, PROFINET, or EtherCAT without additional interface cards. The power section can deliver up to 54 A of peak current, a capacity matched to medium-inertia motors that see short acceleration bursts. Input power is accepted from a three-phase supply at 3 × AC 200–500 V ±10%, so the controller can be used on both 230 V and 400 V plant grids. An IP20 housing permits installation inside a switch cabinet where touch-safe terminals are adequate and surrounding cabinet parts provide the needed barrier against direct contact. Thermal management is handled by internal air cooling through an integrated blower, eliminating the need for external ductwork.

The drive ships with a BASIC control section, providing standard position, velocity, and torque functions for general servo applications. DC power is managed through an infeed and feed operation topology, so several drives can share one supply module and return braking energy to the common bus. The unit uses design version 1 and supports Hiperface/EnDat 2.1/2.2 transducers through dual encoder ports. This allows redundant feedback arrangements or gantry master-slave operation without additional interface cards. The encoder options also help when the drive must work with different motor feedback formats across a machine platform.

Communication Interface
MultiEthernet
Control Section Design Type
BASIC
Cooling Method
Air, internal (through integrated blower)
Design Version
1
Device Peak Current
54 A
Firmware Order Note
Firmware must be ordered as separate sub position
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Interface 2 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
IP Rating
IP20
Line Series
HCS01
Mains Voltage
3 x AC 200...500 V ±10%
Other Design Features
None
Pairing Note
Paired with Control Section Design 'BASIC' (B)
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
  • HCS011EW0054A03BETECECSBNNFW
  • HCS01 1E W0054 A 03 B ET EC EC SB NN FW
  • hcs01.1e-w0028-a-03-b-et-ec-pb-nn-aa-fw
  • HCS1.1E-W0054-A-03-B-ET-EC-EC-SB-NN-FW

Frequently Asked Questions about HCS01.1E-W0054-A-03-B-ET-EC-EC-SB-NN-FW:

Q: What communication interface does the HCS01.1E-W0054-A-03-B-ET-EC-EC-SB-NN-FW drive controller use?

A: The HCS01.1E-W0054-A-03-B-ET-EC-EC-SB-NN-FW supports MultiEthernet communication for versatile network connectivity.

Q: What is the device peak current of the HCS01.1E-W0054-A-03-B-ET-EC-EC-SB-NN-FW?

A: This drive controller supports a peak current of 54 A, allowing for high current loads.

Q: How is the HCS01.1E-W0054-A-03-B-ET-EC-EC-SB-NN-FW cooled?

A: The cooling method for this unit is internal air cooling through an integrated blower.

Q: What is the IP rating of the HCS01.1E-W0054-A-03-B-ET-EC-EC-SB-NN-FW?

A: This model features an IP20 rating, indicating limited protection against solid objects and no protection from liquids.

Q: What is the mains voltage requirement for the HCS01.1E-W0054-A-03-B-ET-EC-EC-SB-NN-FW?

A: The mains voltage requirement is 3-phase AC 200 to 500 V with a tolerance of ±10%.


Internal Product Review

  • ‘‘The HCS01.1E-W0054-A-03-B-ET-EC-EC-SB-NN-FW is a Bosch Rexroth IndraDrive controller featuring MultiEthernet communication and a peak current of 54 A, making it suitable for demanding automation environments. The integrated internal blower provides effective air cooling, and the unit maintains an IP20 rating for reliable protection in control cabinets. This controller stands out for its flexible connectivity and high current capacity.’’