The Bosch Rexroth Indramat HCS01.1E-W0054-A-03-B-ET-EC-EC-S4-NN-FW is a drive controller from the HCS IndraDrive Controllers series. It features a 54 Amp peak current and is designed for a mains voltage of 3 x AC 200 to 500 Volts. The controller uses MultiEthernet communication and has an internal air cooling system through an integrated blower.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The HCS01.1E-W0054-A-03-B-ET-EC-EC-S4-NN-FW is a drive controller manufactured by Bosch Rexroth Indramat for the HCS IndraDrive Controllers series. It bridges the plant’s AC mains with synchronous or induction motors and performs closed-loop torque, speed, and position control for coordinated axes in material-handling and packaging lines. The housing combines power conversion, logic, and diagnostic circuitry in one unit, which helps reduce cabinet wiring and provides onboard status reporting together with fieldbus communication.
The controller exchanges motion commands and status data over a MultiEthernet interface, allowing integration into EtherNet/IP, PROFINET, or EtherCAT networks without additional hardware. Thermal management is handled by internal air cooling through an integrated blower, eliminating the need for external ducting. During rapid acceleration, the inverter can deliver a peak current of 54 A, providing headroom for transient load demands. The enclosure has an IP20 rating, so it is protected against solid objects larger than 12.5 mm and must be installed in a closed electrical cabinet. Incoming power is accepted from a three-phase supply of 3 x AC 200…500 V ±10%, allowing use on low- or medium-voltage distribution systems common in industrial facilities.
The control section is type BASIC, which covers general motion tasks without advanced optional functions. The drive is version 1 within the HCS01 line. Both encoder sockets support IndraDyn Hiperface/EnDat 2.1/2.2 feedback formats, allowing the unit to read absolute position data from compatible Rexroth motors or third-party transducers. Power exchange with the DC bus uses an infeeding and fed supply concept, so the unit can receive regenerated energy from other drives or return excess energy to the bus during axis deceleration.
Frequently Asked Questions about HCS01.1E-W0054-A-03-B-ET-EC-EC-S4-NN-FW:
Q: What type of communication interface does the HCS01.1E-W0054-A-03-B-ET-EC-EC-S4-NN-FW controller use?
A: The HCS01.1E-W0054-A-03-B-ET-EC-EC-S4-NN-FW supports MultiEthernet communication for network connectivity.
Q: How is the HCS01.1E-W0054-A-03-B-ET-EC-EC-S4-NN-FW kept cool during operation?
A: This drive controller features an internal air cooling method utilizing an integrated blower.
Q: What is the peak current output for the HCS01.1E-W0054-A-03-B-ET-EC-EC-S4-NN-FW controller?
A: The HCS01.1E-W0054-A-03-B-ET-EC-EC-S4-NN-FW provides a peak current of 54 A for demanding drive applications.
Q: What mains voltage range is required for the HCS01.1E-W0054-A-03-B-ET-EC-EC-S4-NN-FW?
A: The HCS01.1E-W0054-A-03-B-ET-EC-EC-S4-NN-FW operates at a mains voltage of 3 x AC 200 to 500 V ±10%.
Q: What is the IP rating of the HCS01.1E-W0054-A-03-B-ET-EC-EC-S4-NN-FW controller?
A: This controller is rated IP20, providing basic protection against solid objects but not against liquids.