The Bosch Rexroth Indramat HCS01.1E-W0054-A-03-B-ET-EC-EC-NN-NN-FW is a drive controller in the HCS IndraDrive Controllers series. It features a MultiEthernet communication interface, 54 amp device peak current, and operates at mains voltages from 200 to 500 volts AC. The controller uses an internal air cooling method with an integrated blower and is rated IP20 for protection.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The HCS01.1E-W0054-A-03-B-ET-EC-EC-NN-NN-FW is a drive controller produced by Bosch Rexroth Indramat in the HCS IndraDrive Controllers series. As an IndraDrive axis supply, it converts three-phase AC line power into regulated output for synchronous and induction motors used in packaging, material handling, and machining cells. The unit belongs to the compact HCS01 line, which supports space-saving cabinet layouts while combining the control section and power stage in one housing. It is intended for applications that need closed-loop speed and torque regulation without a separate axis electronics package.

In operation, communication with higher-level PLCs is handled through a MultiEthernet port that supports several real-time fieldbus protocols without additional hardware. The control section in this model is the BASIC variant, which provides standard motion functions and parameter storage for common axis tasks. When short-term load peaks occur, the converter can deliver a device peak current of 54 A, and it remains compatible with supplies from 3 x AC 200 to 500 V ±10%. The unit has an IP20 enclosure, so it must be installed inside a suitable electrical cabinet. This open housing is intended for protected panel installation rather than direct exposure to dust or washdown conditions. The controller does not include an integrated safety interface, so STO must be handled by external safety hardware.

Thermal management uses internal air cooling through an integrated blower, which removes heat without requiring ducted cabinet airflow. Both feedback sockets accept Encoder IndraDyn Hiperface/EnDat 2.1/2.2 signals, supporting single-cable motor wiring and automatic electronic nameplate reading. DC-link energy exchange uses an infeeding and fed supply concept, allowing the HCS01 unit to act as either a rectifier or a consumer within a multi-axis system. This arrangement supports shared energy flow between compatible axes on the same drive network. The unit is Version 1.

Communication Interface
MultiEthernet
Control Section Design Type
BASIC
Cooling Method
Air, internal (through integrated blower)
Design Version
1
Device Peak Current
54 A
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Interface 2 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
IP Rating
IP20
Line Series
HCS01
Mains Voltage
3 x AC 200...500 V ±10%
Other Design Features
None
Pairing Note
Paired with Control Section Design 'BASIC' (B)
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
Safety Interface
Not equipped
  • HCS011EW0054A03BETECECNNNNFW
  • HCS01 1E W0054 A 03 B ET EC EC NN NN FW
  • hcs01.1e-w0028-a-03-b-et-ec-nn-s5-nn-fw
  • HCS1.1E-W0054-A-03-B-ET-EC-EC-NN-NN-FW

Frequently Asked Questions about HCS01.1E-W0054-A-03-B-ET-EC-EC-NN-NN-FW:

Q: What communication interface is available on the HCS01.1E-W0054-A-03-B-ET-EC-EC-NN-NN-FW controller?

A: The HCS01.1E-W0054-A-03-B-ET-EC-EC-NN-NN-FW supports MultiEthernet for versatile network connectivity.

Q: How is the HCS01.1E-W0054-A-03-B-ET-EC-EC-NN-NN-FW drive controller cooled?

A: This model utilizes air cooling through an integrated blower for internal cooling.

Q: What is the device peak current for the HCS01.1E-W0054-A-03-B-ET-EC-EC-NN-NN-FW model?

A: The peak current capability for this drive controller is 54 A.

Q: What encoder interfaces are provided on the HCS01.1E-W0054-A-03-B-ET-EC-EC-NN-NN-FW?

A: Both Interface 1 and 2 support IndraDyn Hiperface or EnDat 2.1/2.2 encoders.

Q: What is the supported mains voltage for the HCS01.1E-W0054-A-03-B-ET-EC-EC-NN-NN-FW?

A: This drive controller operates on a mains voltage range of 3 x AC 200 to 500 V with a tolerance of ±10%.


Internal Product Review

  • ‘‘The HCS01.1E-W0054-A-03-B-ET-EC-EC-NN-NN-FW is a well-engineered HCS drive controller with internal air cooling for dependable thermal management. MultiEthernet communication supports efficient network integration in motion control systems. A 54 A peak current rating and 3 x AC 200 to 500 V mains input make this unit a strong choice for demanding drive applications.’’