HCS01.1E-W0054-A-03-B-ET-EC-EC-NN-NN-AW Bosch Rexroth Indramat
MPN: R911387261
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The Bosch Rexroth Indramat HCS01.1E-W0054-A-03-B-ET-EC-EC-NN-NN-AW is an HCS Drive Controller from the HCS IndraDrive Controllers series. It features a MultiEthernet communication interface and supports IndraDyn Hiperface and EnDat 2.1/2.2 encoder interfaces. The unit has a device peak current of 54 Amps, an IP20 rating, and uses internal air cooling with an integrated blower.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The HCS01.1E-W0054-A-03-B-ET-EC-EC-NN-NN-AW is a drive controller manufactured by Bosch Rexroth Indramat and assigned to the HCS IndraDrive Controllers series. Installed between the mains supply and servo or induction motors, it converts and modulates energy so motion axes can follow velocity or position commands from the machine control system. It regulates output for closed-loop drive tasks while supporting both dynamic speed changes and accurate positional response. In automated packaging lines, material-handling cells, and process equipment, the unit also exchanges diagnostics and parameter data through its integrated communication bus.
The controller accepts a three-phase supply of 3 x AC 200...500 V ±10%, allowing the same hardware to be connected to low- or medium-voltage plant networks. During rapid acceleration or regenerative events, the power stage can deliver up to 54 A of peak current, giving margin for dynamic load changes before current limiting activates. Fieldbus integration is handled by a MultiEthernet interface that supports common industrial Ethernet protocols without extra option cards. The housing meets IP20, so the unit must be mounted in an electrical cabinet while airflow remains available for heat removal.
The controller belongs to the HCS01 line and carries design version 1, so its dimensions and screw patterns match other first-generation frames. Its control section is the BASIC variant, which provides standard drive functions without a safety extension, and the dedicated safety interface is not equipped. Thermal management relies on internal air cooling through an integrated blower, eliminating the need for external ducting. Two identical feedback ports accept Encoder IndraDyn Hiperface/EnDat 2.1/2.2 signals, supporting single-cable or separate-cable motor encoders across both axes. The unit uses an infeeding and fed supply arrangement, so multiple drives can share regenerative power through the DC bus.
Frequently Asked Questions about HCS01.1E-W0054-A-03-B-ET-EC-EC-NN-NN-AW:
Q: What type of communication interface does this HCS IndraDrive Controller support?
A: The HCS01.1E-W0054-A-03-B-ET-EC-EC-NN-NN-AW features MultiEthernet communication for connecting to various industrial networks.
Q: What is the peak current rating of the HCS01.1E-W0054-A-03-B-ET-EC-EC-NN-NN-AW?
A: This drive controller offers a device peak current of 54 A for demanding automation tasks.
Q: How is the HCS01.1E-W0054-A-03-B-ET-EC-EC-NN-NN-AW cooled during operation?
A: The unit uses internal air cooling with an integrated blower for temperature control.
Q: What types of encoder interfaces are provided on this drive controller?
A: Both encoder interfaces on this model support IndraDyn Hiperface and EnDat 2.1/2.2 for feedback options.
Q: What mains voltage range is supported by this IndraDrive controller?
A: The HCS01.1E-W0054-A-03-B-ET-EC-EC-NN-NN-AW supports a mains voltage range of 3 x AC 200...500 V with a tolerance of ±10%.