The Bosch Rexroth Indramat HCS01.1E-W0054-A-03-B-ET-EC-CN-S4-NN-FW is part of the HCS IndraDrive Controllers series. This drive controller has a device peak current of 54 Amps and supports a mains voltage range of 3 x AC 200 to 500 Volts. It features MultiEthernet and CANopen communication interfaces, and uses air cooling through an integrated blower.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The drive controller HCS01.1E-W0054-A-03-B-ET-EC-CN-S4-NN-FW belongs to the HCS IndraDrive Controllers series developed by Bosch Rexroth Indramat. Within an automation cell, this unit supplies regulated power and motion commands to connected servo or induction motors, coordinating speed, position, and torque according to higher-level PLC instructions. By combining a compact power stage with a detachable control section, it lets the system use a consistent cabinet footprint while adapting the axis to the application.
The controller accepts communication through a MultiEthernet port, so the same hardware can support PROFINET, EtherNet/IP, or EtherCAT without rewiring. Its mains input spans 3 × AC 200…500 V ±10%, allowing installation on a wide range of industrial power systems without a step-down transformer. The current stage can deliver up to 54 A of peak output to handle rapid accelerations or short overloads. The housing is rated IP20, which leaves terminals accessible for cabinet wiring but requires installation inside a protected enclosure. Internal thermal management uses internal air cooling through an integrated blower, and the blower moves cabinet air across the heat sinks to remove dissipation losses.
The exchangeable control section is the BASIC variant, providing standard axis functions with a straightforward control setup. Feedback signals arrive through a multifunction port that supports IndraDyn Hiperface and EnDat 2.1/2.2 encoder feedback, allowing high-resolution position control without additional interface cards. Fieldbus diagnostics and I/O mapping can also be accessed through the dedicated CANopen connector for legacy network segments. Power is supplied through the common DC bus in an infeeding and fed topology, so multiple drives can share one supply and exchange regenerative energy during deceleration.
Frequently Asked Questions about HCS01.1E-W0054-A-03-B-ET-EC-CN-S4-NN-FW:
Q: What type of communication interface does the HCS01.1E-W0054-A-03-B-ET-EC-CN-S4-NN-FW drive controller use?
A: The HCS01.1E-W0054-A-03-B-ET-EC-CN-S4-NN-FW uses MultiEthernet for its communication interface.
Q: What cooling method is implemented in the HCS01.1E-W0054-A-03-B-ET-EC-CN-S4-NN-FW controller?
A: This drive controller is cooled internally by air using an integrated blower.
Q: Which design version does the HCS01.1E-W0054-A-03-B-ET-EC-CN-S4-NN-FW belong to?
A: The design version of the HCS01.1E-W0054-A-03-B-ET-EC-CN-S4-NN-FW is Version 1.
Q: What is the peak current rating for the HCS01.1E-W0054-A-03-B-ET-EC-CN-S4-NN-FW drive controller?
A: The drive controller can handle a device peak current of 54 A.
Q: What mains voltage range can the HCS01.1E-W0054-A-03-B-ET-EC-CN-S4-NN-FW operate on?
A: The mains voltage supported is 3 x AC 200 to 500 V with a ±10% tolerance.