4.95 based on 202 reviews

🙶 a+ fast delivery 🙷

HCS01.1E-W0054-A-03-B-ET-EC-CN-NN-NN-FW Bosch Rexroth Indramat

MPN: R911335874

No Tariffs On US Orders
  • Rated 4.4 (46 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
Available, Ships in 1-2 weeks

Preparing your secure checkout page...

The Bosch Rexroth Indramat HCS01.1E-W0054-A-03-B-ET-EC-CN-NN-NN-FW is part of the HCS IndraDrive Controllers series and features a MultiEthernet communication interface. With an IP20 rating and a device peak current of 54 Amps, this drive controller operates on a mains voltage of 3 x AC 200 to 500 Volts. It is designed with air cooling through an integrated blower and includes encoder interfaces compatible with IndraDyn Hiperface and EnDat 2.1 or 2.2.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The HCS01.1E-W0054-A-03-B-ET-EC-CN-NN-NN-FW is an HCS Drive Controller manufactured by Bosch Rexroth Indramat within the HCS IndraDrive Controllers series. In automated plants, it links the mains supply to motion commands created by a PLC or CNC. It regulates speed and torque on synchronous or asynchronous motors so that machine axes follow their commanded profiles with the required accuracy. The unit is intended for closed-loop motion tasks where stable motor control and repeatable axis response are required.

Electrically, the controller accepts a three-phase supply of 3 x AC 200…500 V ±10%, enabling operation on a wide range of utility grids. From that input, it delivers up to 54 A of peak current, which suits mid-power single-axis stations and compact multi-axis groups. Control logic resides in a BASIC section that is factory paired to the power stage, which keeps the internal configuration consistent. High-level networks are provided by MultiEthernet, which supports several real-time Ethernet protocols on one port. Thermal management relies on internal air cooling through an integrated blower, and the metal housing has an IP20 rating, so the unit requires cabinet mounting. The unit is Design Version 1 and uses an infeeding power topology for the drive section.

Feedback and auxiliary buses are routed through two dedicated sockets. The first supports Encoder IndraDyn Hiperface/EnDat 2.1/2.2 for absolute position data, and the second offers CANopen for decentralized I/O or legacy drive chains. This arrangement allows motor feedback and peripheral communication to remain on separate interfaces during operation. The unit belongs to the HCS01 line. No integrated safety interface is installed, so external safety functions must be provided by other system components when the application requires them. Cabinet installation requires proper bus termination and sufficient airflow around the housing.

Communication Interface
MultiEthernet
Control Section Design Type
BASIC
Cooling Method
Air, internal (through integrated blower)
Design Version
1
Device Peak Current
54 A
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Interface 2 Type
CANopen
IP Rating
IP20
Line Series
HCS01
Mains Voltage
3 x AC 200...500 V ±10%
Other Design Features
None
Pairing Note
Paired with Control Section Design 'BASIC' (B)
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
Safety Interface
Not equipped
  • HCS011EW0054A03BETECCNNNNNFW
  • HCS01 1E W0054 A 03 B ET EC CN NN NN FW
  • hcs01.1e-w0028-a-03-b-et-ec-nn-nn-nn-aw
  • HCS1.1E-W0054-A-03-B-ET-EC-CN-NN-NN-FW

Frequently Asked Questions about HCS01.1E-W0054-A-03-B-ET-EC-CN-NN-NN-FW:

Q: What communication interface is available on the HCS01.1E-W0054-A-03-B-ET-EC-CN-NN-NN-FW drive controller?

A: The HCS01.1E-W0054-A-03-B-ET-EC-CN-NN-NN-FW supports MultiEthernet as its communication interface for network integration.

Q: What is the peak current supported by the HCS01.1E-W0054-A-03-B-ET-EC-CN-NN-NN-FW controller?

A: This drive controller is capable of handling a peak current of 54 A.

Q: How is the HCS01.1E-W0054-A-03-B-ET-EC-CN-NN-NN-FW drive controller cooled?

A: The cooling is handled by internal air through an integrated blower system.

Q: What is the IP rating of the HCS01.1E-W0054-A-03-B-ET-EC-CN-NN-NN-FW drive controller?

A: This model has an IP20 protection rating, offering limited protection against solid foreign objects.

Q: What mains voltage range does the HCS01.1E-W0054-A-03-B-ET-EC-CN-NN-NN-FW support?

A: The HCS01.1E-W0054-A-03-B-ET-EC-CN-NN-NN-FW operates with a mains voltage range of 3 x AC 200...500 V ±10%.


Internal Product Review

  • ‘‘The HCS01.1E-W0054-A-03-B-ET-EC-CN-NN-NN-FW is an HCS drive controller with MultiEthernet communication and a BASIC control section. Internal blower cooling and IP20 protection support dependable cabinet operation in demanding automation panels. A 54 A peak current and 3 x AC 200...500 V input make the unit a strong choice for flexible IndraDrive installations.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo