4.95 based on 202 reviews

🙶 First-time customer with Wake Industrial. The ordering process was completely seamless. The part that we o... 🙷

HCS01.1E-W0054-A-03-A-ET-EC-NN-NN-NN-FW Bosch Rexroth Indramat

MPN: R911387201

No Tariffs On US Orders
  • Rated 4.5 (65 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
Ask for Availability

Preparing your secure checkout page...

The Bosch Rexroth Indramat HCS01.1E-W0054-A-03-A-ET-EC-NN-NN-NN-FW is part of the HCS IndraDrive Controllers series. This HCS drive controller supports a MultiEthernet communication interface and operates with an internal blower for air cooling. It delivers a peak current of 54 Amps, has IP20 protection, and works with a mains voltage of 3 x AC 200 to 500 Volts.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The HCS01.1E-W0054-A-03-A-ET-EC-NN-NN-NN-FW is a servo drive controller built by Bosch Rexroth Indramat in the HCS IndraDrive Controllers series. Within an automation cell, the unit forms the interface between the plant PLC and a connected motor, executing speed, torque, and position commands in real time. In this role, it converts high-level motion requests into regulated motor current so the axis can follow commanded profiles with stable response. Its HCS01 design supports decentralized cabinet layouts where multiple axes share common DC links while retaining individual regulation, making the device suitable for assembly stations, handling modules, and packaging machinery.

The controller accepts a mains input of 3 x AC 200...500 V ±10%, allowing operation on three-phase supplies without rewiring. During acceleration or braking, the power stage can deliver up to 54 A of peak current, giving added headroom for short dynamic moves on compact mechanical axes. Fieldbus communication is routed through the MultiEthernet port, which can switch between Sercos, EtherNet/IP, PROFINET, or TCP/IP topologies so the same unit can communicate across different industrial Ethernet systems. Thermal stability is maintained by internal air cooling through an integrated blower, and the IP20 housing is intended for clean cabinet environments with finger-safe clearances around live parts.

The drive uses hardware revision 1, which indicates the mechanical footprint used across this product line. Its feedback interface accepts IndraDyn Hiperface and EnDat 2.1/2.2 encoder signals for high-resolution position loops. Power is exchanged with the DC bus through an infeeding and fed topology, enabling energy sharing and regenerative braking when several drives operate together on the same bus. The control section is marked BASIC, and no second interface or safety channel is installed, so Interface 2 and the safety connection are left open.

Communication Interface
MultiEthernet
Cooling Method
Air, internal (through integrated blower)
Design Version
1
Device Peak Current
54 A
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Interface 2 Type
Not equipped
IP Rating
IP20
Line Series
HCS01
Mains Voltage
3 x AC 200...500 V ±10%
Other Design Features
None
Pairing Note
Paired with Control Section Design 'BASIC' (B)
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
Safety Interface
Not equipped
  • HCS011EW0054A03AETECNNNNNNFW
  • HCS01 1E W0054 A 03 A ET EC NN NN NN FW
  • hcs01.1e-w0028-a-03-b-et-ec-nn-l4-aa-fw
  • HCS1.1E-W0054-A-03-A-ET-EC-NN-NN-NN-FW

Frequently Asked Questions about HCS01.1E-W0054-A-03-A-ET-EC-NN-NN-NN-FW:

Q: What communication interface is available on the HCS01.1E-W0054-A-03-A-ET-EC-NN-NN-NN-FW?

A: The HCS01.1E-W0054-A-03-A-ET-EC-NN-NN-NN-FW supports MultiEthernet communication for versatile network integration.

Q: What is the device peak current of the HCS01.1E-W0054-A-03-A-ET-EC-NN-NN-NN-FW?

A: This controller provides a peak current of 54 A, suitable for high-demand drive applications.

Q: How is the HCS01.1E-W0054-A-03-A-ET-EC-NN-NN-NN-FW cooled?

A: The internal air cooling system uses an integrated blower for maintaining optimal operating temperature.

Q: What is the mains voltage range for the HCS01.1E-W0054-A-03-A-ET-EC-NN-NN-NN-FW?

A: It operates with an input mains voltage range of 3 x AC 200 to 500 V ±10%.

Q: What IP rating does the HCS01.1E-W0054-A-03-A-ET-EC-NN-NN-NN-FW have?

A: The unit features an IP20 rating, offering basic protection against solid objects but not against water.


Internal Product Review

  • ‘‘The HCS01.1E-W0054-A-03-A-ET-EC-NN-NN-NN-FW is an HCS drive controller with MultiEthernet communication for streamlined network integration. Internal air cooling through an integrated blower and a 54 A peak current support stable drive performance under dynamic load conditions. IP20 protection and 3 x AC 200...500 V mains compatibility make the unit a strong choice for modern cabinet-based automation systems.’’