4.95 based on 202 reviews

🙶 We have never had a problem in the almost 20 years we have dealt with Wake. We would recommend them to any... 🙷

HCS01.1E-W0054-A-03-A-ET-EC-EC-NN-NN-FW Bosch Rexroth Indramat

MPN: R911376773

No Tariffs On US Orders
  • Rated 4.5 (57 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
Ask for Availability

Preparing your secure checkout page...

The Bosch Rexroth Indramat HCS01.1E-W0054-A-03-A-ET-EC-EC-NN-NN-FW is a drive controller from the HCS IndraDrive Controllers series. It features MultiEthernet communication, operates with a peak current of 54 Amps, and uses internal air cooling through an integrated blower. This model supports encoder interfaces for IndraDyn Hiperface and EnDat 2.1/2.2, and has an IP20 rating.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The HCS01.1E-W0054-A-03-A-ET-EC-EC-NN-NN-FW is a drive controller produced by Bosch Rexroth Indramat within the HCS IndraDrive Controllers series. As an HCS drive controller, it regulates DC bus energy and performs closed-loop motor control for automated production lines, packaging equipment, and material-handling systems. Its role is to convert incoming supply power into controlled motor output while maintaining stable response to changing loads and commanded motion profiles. It is suited for cabinet-mounted motion applications that need coordinated speed, torque, and position control from a compact single-axis platform.

The mains input is 3 × AC 200…500 V ±10%, allowing the unit to operate on common 230 V and 460 V installations without a transformer. During acceleration peaks, the power stage can deliver 54 A of peak current to the connected axis. Thermal management uses internal air cooling from an integrated blower, so no external coolant circuit is required. Network integration is handled through a MultiEthernet port that supports industrial communication protocols for synchronized motion and diagnostics. Two identical feedback ports accept Encoder IndraDyn Hiperface or EnDat 2.1/2.2 signals, allowing the controller to close position loops directly from high-resolution transducers. The housing has an IP20 rating, so the unit must be installed inside a control cabinet that provides additional protection. Because the cooling air is generated internally, the surrounding enclosure still needs a clear airflow path so heat can leave the cabinet effectively.

This hardware is classified as Design Version 1 in the HCS01 line, which indicates the first mechanical and electrical revision. Its power section operates in an Infeeding/Feeded topology, which allows regenerated energy to return to the DC bus during deceleration. The device is intended to be paired with a control section designated BASIC, which provides the application-specific control functions and parameter handling. A dedicated safety interface is not installed, so external safety circuits must interrupt the drive-enable signals when that function is required.

Communication Interface
MultiEthernet
Cooling Method
Air, internal (through integrated blower)
Design Version
1
Device Peak Current
54 A
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Interface 2 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
IP Rating
IP20
Line Series
HCS01
Mains Voltage
3 x AC 200...500 V ±10%
Other Design Features
None
Pairing Note
Paired with Control Section Design 'BASIC' (B)
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
Safety Interface
Not equipped
  • HCS011EW0054A03AETECECNNNNFW
  • HCS01 1E W0054 A 03 A ET EC EC NN NN FW
  • hcs01.1e-w0028-a-03-b-et-ec-ep-s4-nn-aw
  • HCS1.1E-W0054-A-03-A-ET-EC-EC-NN-NN-FW

Frequently Asked Questions about HCS01.1E-W0054-A-03-A-ET-EC-EC-NN-NN-FW:

Q: What communication interface does the HCS01.1E-W0054-A-03-A-ET-EC-EC-NN-NN-FW drive controller use?

A: This model supports MultiEthernet communication, allowing integration into various network protocols.

Q: How is the HCS01.1E-W0054-A-03-A-ET-EC-EC-NN-NN-FW drive controller cooled?

A: The cooling is accomplished via an internal air system with an integrated blower.

Q: What is the peak current capacity of the HCS01.1E-W0054-A-03-A-ET-EC-EC-NN-NN-FW controller?

A: This unit delivers a device peak current of 54 A, providing substantial power output.

Q: What mains voltage does the HCS01.1E-W0054-A-03-A-ET-EC-EC-NN-NN-FW drive controller support?

A: The HCS01.1E-W0054-A-03-A-ET-EC-EC-NN-NN-FW operates on a three-phase AC voltage range of 200 to 500 V ±10%.

Q: What is the IP rating of the HCS01.1E-W0054-A-03-A-ET-EC-EC-NN-NN-FW controller?

A: The enclosure has an IP20 rating, which means it is protected against solid objects larger than 12 mm but not against water.


Internal Product Review

  • ‘‘The HCS01.1E-W0054-A-03-A-ET-EC-EC-NN-NN-FW is a Bosch Rexroth Indramat HCS drive controller with internal air cooling. MultiEthernet communication and dual IndraDyn Hiperface/EnDat 2.1/2.2 encoder interfaces support precise integration in networked motion systems. The 54 A peak current gives the controller strong dynamic capability for demanding servo applications.’’