4.95 based on 202 reviews

🙶 Excellent to work with and they stand behind their work. I would highly recommend them. 🙷

HCS01.1E-W0054-A-03-A-CC-EC-PB-L4-NN-FW Bosch Rexroth Indramat

MPN: R911394321

No Tariffs On US Orders
  • Rated 4.5 (42 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
Ask for Availability

Preparing your secure checkout page...

The Bosch Rexroth Indramat HCS01.1E-W0054-A-03-A-CC-EC-PB-L4-NN-FW is part of the HCS IndraDrive Controllers series. This drive controller has a peak current of 54 Amps and features both SERCOS III and PROFIBUS communication interfaces. It is equipped with an encoder interface supporting IndraDyn Hiperface and EnDat, and provides STO and SBC safety functions with an IP20 protection rating.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The HCS01.1E-W0054-A-03-A-CC-EC-PB-L4-NN-FW is manufactured by Bosch Rexroth Indramat for the HCS IndraDrive Controllers series. The device belongs to the compact HCS01 line and acts as a drive controller that converts facility power into precisely regulated current for servo and induction motors in automated machinery. By combining power electronics, communication hardware, and safety circuits in one enclosure, it reduces cabinet wiring and supports coordinated axis motion with a central PLC. Its compact format suits installations where drive electronics must fit into limited panel space without separating key control and power functions.

Design version 1 is combined with the control section marked ADVANCED, which supports extended motion functions. The power stage can supply 54 A of peak current to the attached axis, while current regulators help keep the motor within thermal limits during changing load conditions. The unit accepts an input supply of 3 x AC 200...500 V with a tolerance of ±10%, so the same controller can be used on common 230 V and 400 V systems. Component protection is limited to IP20, which means the drive must be mounted inside an enclosure to prevent contact with internal parts. Time-critical motion data is exchanged through a SERCOS III master interface, and heat from the IGBTs is removed by an integrated blower instead of external fans.

The drive accepts position feedback through the Encoder IndraDyn Hiperface/EnDat 2.1/2.2 port, and non-real-time control messages can also arrive over PROFIBUS. Functional safety is covered by STO and SBC, allowing the controller to remove torque and control the brake through certified channels. The power section is classified as Infeeding / Feeded, so it can absorb regenerated energy and return it to a shared DC bus. This arrangement supports multi-axis systems in which braking energy from one axis can be used elsewhere on the DC link instead of being dissipated locally.

Communication Interface
SERCOS III master (cross communication)
Control Section Design Type
ADVANCED
Cooling Method
Air, internal (through integrated blower)
Design Version
1
Device Peak Current
54 A
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Interface 2 Type
PROFIBUS
IP Rating
IP20
Line Series
HCS01
Mains Voltage
3 x AC 200...500 V ±10%
Other Design Features
None
Pairing Note
Paired with Control Section Design 'ADVANCED' (A)
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
Safety Interface
STO (Safe Torque Off) and SBC (Safe Brake Control)
  • HCS011EW0054A03ACCECPBL4NNFW
  • HCS01 1E W0054 A 03 A CC EC PB L4 NN FW
  • hcs01.1e-w0028-a-03-b-et-ec-em-sb-nn-fw
  • HCS1.1E-W0054-A-03-A-CC-EC-PB-L4-NN-FW

Frequently Asked Questions about HCS01.1E-W0054-A-03-A-CC-EC-PB-L4-NN-FW:

Q: Which communication interface is used by the HCS01.1E-W0054-A-03-A-CC-EC-PB-L4-NN-FW controller?

A: The HCS01.1E-W0054-A-03-A-CC-EC-PB-L4-NN-FW supports SERCOS III master for cross communication, enabling advanced connectivity.

Q: What is the device peak current of the HCS01.1E-W0054-A-03-A-CC-EC-PB-L4-NN-FW?

A: This drive controller has a peak current capability of 54 A, supporting high-demand applications.

Q: How is the HCS01.1E-W0054-A-03-A-CC-EC-PB-L4-NN-FW cooled?

A: The HCS01.1E-W0054-A-03-A-CC-EC-PB-L4-NN-FW uses an integrated blower for internal air cooling.

Q: What level of protection does the IP rating provide for the HCS01.1E-W0054-A-03-A-CC-EC-PB-L4-NN-FW?

A: This controller provides IP20 protection against solid foreign objects greater than 12.5 mm but does not protect against water.

Q: Which safety interfaces are available on the HCS01.1E-W0054-A-03-A-CC-EC-PB-L4-NN-FW?

A: The safety features include Safe Torque Off (STO) and Safe Brake Control (SBC) for enhanced operator and machine safety.


Internal Product Review

  • ‘‘The HCS01.1E-W0054-A-03-A-CC-EC-PB-L4-NN-FW is an HCS drive controller engineered for demanding motion control duty. An internal air blower supports consistent thermal management, and the 54 A peak current gives the unit strong dynamic capability. SERCOS III master cross communication and integrated STO/SBC functions make the controller a highly capable choice for advanced machine architectures.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo