4.95 based on 202 reviews

🙶 First-time customer with Wake Industrial. The ordering process was completely seamless. The part that we o... 🙷

HCS01.1E-W0054-A-03-A-CC-EC-NN-L4-NN-FW Bosch Rexroth Indramat

MPN: R911338071

No Tariffs On US Orders
  • Rated 4.5 (71 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
Ask for Availability

Preparing your secure checkout page...

The Bosch Rexroth Indramat HCS01.1E-W0054-A-03-A-CC-EC-NN-L4-NN-FW is part of the HCS IndraDrive Controllers series and is an advanced HCS drive controller. It supports SERCOS III communication, uses an internal air cooling system with an integrated blower, and has an IP20 rating. The device features a peak current of 54 Amps, encoder interface options for IndraDyn Hiperface or EnDat, and safety functions including Safe Torque Off and Safe Brake Control.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The HCS01.1E-W0054-A-03-A-CC-EC-NN-L4-NN-FW drive controller is produced by Bosch Rexroth Indramat within the HCS IndraDrive Controllers series. This HCS01 unit converts three-phase supply power into regulated motor current, enabling precise torque and speed control on automated machine axes. Its modular structure combines a power base with a detachable control section, which allows motion control, safety, and communication functions to be integrated in one cabinet-mounted device. That layout also separates the control electronics from the power section, which helps keep wiring organized in multi-axis installations.

It accepts a mains window of 3 x AC 200 to 500 V ±10%, allowing the same hardware to connect to common industrial power systems across a wide voltage range. The power stage can deliver up to 54 A of peak output current during brief acceleration demands before thermal limiting intervenes. Heat is removed by internal air cooling through an integrated blower, so no external ducting is required around the drive housing. Field communication is handled by a SERCOS III master channel that supports synchronized motion and cross-communication among adjacent drives. The plugged control section is the ADVANCED type, which provides the control platform used for the unit’s communication and operating functions.

Protection against accidental contact is provided by the IP20 housing when the unit is installed inside a closed control cabinet. For axis feedback, Interface 1 provides IndraDyn Hiperface and EnDat 2.1/2.2 encoder support, while the second interface slot is left unequipped when only one sensor channel is needed. Integrated functional safety is provided by STO and SBC, which remove drive torque and control the motor brake without external relay logic. The power module also supports infeeding and fed operation, allowing regenerated energy to be returned to the mains or shared on a common DC bus with other connected axes.

Communication Interface
SERCOS III master (cross communication)
Control Section Design Type
ADVANCED
Cooling Method
Air, internal (through integrated blower)
Design Version
1
Device Peak Current
54 A
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Interface 2 Type
Not equipped
IP Rating
IP20
Line Series
HCS01
Mains Voltage
3 x AC 200...500 V ±10%
Other Design Features
None
Pairing Note
Paired with Control Section Design 'ADVANCED' (A)
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
Safety Interface
STO (Safe Torque Off) and SBC (Safe Brake Control)
  • HCS011EW0054A03ACCECNNL4NNFW
  • HCS01 1E W0054 A 03 A CC EC NN L4 NN FW
  • hcs01.1e-w0028-a-03-b-et-ec-em-l4-nn-fw
  • HCS1.1E-W0054-A-03-A-CC-EC-NN-L4-NN-FW

Frequently Asked Questions about HCS01.1E-W0054-A-03-A-CC-EC-NN-L4-NN-FW:

Q: What is the peak current output of the HCS01.1E-W0054-A-03-A-CC-EC-NN-L4-NN-FW IndraDrive controller?

A: The HCS01.1E-W0054-A-03-A-CC-EC-NN-L4-NN-FW provides a device peak current of 54 A.

Q: Which communication interface is available on the HCS01.1E-W0054-A-03-A-CC-EC-NN-L4-NN-FW controller?

A: This model uses SERCOS III master for cross communication as its main communication interface.

Q: How is the HCS01.1E-W0054-A-03-A-CC-EC-NN-L4-NN-FW drive controller cooled?

A: The controller offers an internal air-cooling method through an integrated blower.

Q: What is the IP rating of the HCS01.1E-W0054-A-03-A-CC-EC-NN-L4-NN-FW?

A: The protection level for this drive controller is IP20.

Q: What safety features are included on the HCS01.1E-W0054-A-03-A-CC-EC-NN-L4-NN-FW controller?

A: The safety interface includes STO (Safe Torque Off) and SBC (Safe Brake Control) features.


Internal Product Review

  • ‘‘The HCS01.1E-W0054-A-03-A-CC-EC-NN-L4-NN-FW is an HCS drive controller with an ADVANCED control section design. SERCOS III master cross communication and the integrated STO/SBC safety interface support disciplined motion networking and dependable machine protection. Internal air cooling through an integrated blower and a 54 A peak current make the unit a strong choice for demanding drive applications.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo