4.95 based on 202 reviews

🙶 a+ fast delivery 🙷

HCS01.1E-W0054-A-03-A-CC-EC-ET-S4-NN-FW Bosch Rexroth Indramat

MPN: R911341040

No Tariffs On US Orders
  • Rated 4.5 (46 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
Ask for Availability

Preparing your secure checkout page...

The Bosch Rexroth Indramat HCS01.1E-W0054-A-03-A-CC-EC-ET-S4-NN-FW is part of the HCS IndraDrive Controllers series. This drive controller supports a device peak current of 54 Amps and operates with mains voltage from 200 to 500 Volts AC. It features an IP20 protection rating, MultiEthernet and SERCOS III master interfaces, and uses internal air cooling with an integrated blower.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The HCS01.1E-W0054-A-03-A-CC-EC-ET-S4-NN-FW is a drive controller produced by Bosch Rexroth Indramat within the HCS IndraDrive Controllers series. It serves as an HCS drive controller for regulated motor operation in industrial automation systems. The unit conditions three-phase mains power and executes closed-loop motion commands so connected motors follow precise speed or torque references. By combining power conversion and motion control in one housing, it suits compact cabinet installations that require coordinated axis control and stable motor response.

The controller accepts a nominal supply of 3 x AC 200–500 V ±10% and can momentarily deliver up to 54 A of peak current to the motor inverter stage. Thermal dissipation is handled by internal air cooling through an integrated blower, so no external heat sink is required. The enclosed cooling arrangement helps move heat away from internal components during operation when the unit is installed in a suitable cabinet. Under normal cabinet mounting, it carries an IP20 protection rating, making it suitable for protected electrical enclosures. Command and diagnostic traffic between multiple drives is handled by a SERCOS III interface that supports cross-communication. The power section can operate in either infeeding or energy-recovery mode, depending on the shared DC bus arrangement, and the product is design version 1.

The control section mounted on this power module is classified as ADVANCED, which corresponds to the A identifier in the type code. Motion feedback enters through an Encoder IndraDyn Hiperface/EnDat 2.1/2.2 channel, while real-time fieldbus traffic to higher-level PLCs can also be exchanged over MultiEthernet ports. These communication paths can operate at the same time without external gateways, which helps the controller exchange motion data and network traffic within the HCS01 line. This arrangement supports synchronized operation across connected equipment while keeping the control structure compact and reducing the need for separate interface hardware.

Communication Interface
SERCOS III master (cross communication)
Control Section Design Type
ADVANCED
Cooling Method
Air, internal (through integrated blower)
Design Version
1
Device Peak Current
54 A
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Interface 2 Type
MultiEthernet
IP Rating
IP20
Line Series
HCS01
Mains Voltage
3 x AC 200...500 V ±10%
Other Design Features
None
Pairing Note
Paired with Control Section Design 'ADVANCED' (A)
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
  • HCS011EW0054A03ACCECETS4NNFW
  • HCS01 1E W0054 A 03 A CC EC ET S4 NN FW
  • hcs01.1e-w0028-a-03-b-et-ec-ec-s5-nn-nw
  • HCS1.1E-W0054-A-03-A-CC-EC-ET-S4-NN-FW

Frequently Asked Questions about HCS01.1E-W0054-A-03-A-CC-EC-ET-S4-NN-FW:

Q: How is the HCS01.1E-W0054-A-03-A-CC-EC-ET-S4-NN-FW drive controller cooled?

A: The HCS01.1E-W0054-A-03-A-CC-EC-ET-S4-NN-FW features an internal air cooling method provided by an integrated blower.

Q: What is the device peak current for the HCS01.1E-W0054-A-03-A-CC-EC-ET-S4-NN-FW?

A: This drive controller supports a peak current of 54 A, which is suitable for demanding industrial applications.

Q: What communication interface does the HCS01.1E-W0054-A-03-A-CC-EC-ET-S4-NN-FW utilize?

A: The main communication interface used is a SERCOS III master with cross communication capabilities.

Q: What is the mains voltage range supported by the HCS01.1E-W0054-A-03-A-CC-EC-ET-S4-NN-FW?

A: This controller operates with a mains voltage range of 3 x AC 200 to 500 V with a ±10% tolerance.

Q: What IP rating does the HCS01.1E-W0054-A-03-A-CC-EC-ET-S4-NN-FW have?

A: The unit meets an IP20 rating, providing basic protection against solid objects larger than 12.5 mm.


Internal Product Review

  • ‘‘The HCS01.1E-W0054-A-03-A-CC-EC-ET-S4-NN-FW is an HCS drive controller with an ADVANCED control section and SERCOS III master communication. Internal air cooling through an integrated blower supports stable thermal management, while IP20 protection fits well in controlled cabinet environments. The 54 A peak current rating makes this Bosch Rexroth Indramat controller a strong choice for demanding drive applications.’’