The Bosch Rexroth Indramat HCS01.1E-W0054-A-03-A-CC-EC-EC-S4-NN-FW is part of the HCS IndraDrive Controllers series and features an ADVANCED control section design. This drive controller has an internal air cooling method, supports a peak current of 54 Amps, and has an IP20 rating. It includes a SERCOS III master communication interface with dual encoder interfaces for IndraDyn Hiperface and EnDat 2.1/2.2, and operates at 3-phase AC mains voltages from 200 to 500 Volts.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The HCS01.1E-W0054-A-03-A-CC-EC-EC-S4-NN-FW is a drive controller manufactured by Bosch Rexroth Indramat for the HCS IndraDrive Controllers series. It links plant mains to servo axes and performs current and velocity regulation in automated stations. The unit is part of the HCS01 line and exchanges status data with supervisory PLCs to support coordinated motion in a multi-axis cell. It is suited to machine layouts where several axes must share timing information and operate together during continuous production.
This controller accepts a three-phase supply of 3 x AC 200…500 V ±10%, allowing operation across a wide range of industrial mains. Its power stage can deliver up to 54 A of peak current to the connected motor windings, which supports short acceleration demands and dynamic load changes. Thermal management uses internal air cooling from a built-in blower that moves air through the heat sink fins, and the enclosure carries an IP20 rating for cabinet installation. Cycle and diagnostic data travel over a SERCOS III master link, which supports synchronized communication and cross-communication between controllers in multi-drive arrangements. Because the housing is IP20, the unit should be installed where the surrounding cabinet prevents accidental contact with energized parts.
The control section in this model is the ADVANCED variant, and the unit is design version 1. Two feedback ports accept IndraDyn Hiperface or EnDat 2.1 / 2.2 encoder signals, so position and speed data can be processed directly for closed-loop motion control. DC-bus power exchange supports infeeding and fed operation, allowing the drive either to supply energy to the bus or draw energy from it, depending on the system layout. This arrangement supports shared energy flow in installations where several axes operate from a common DC-bus structure.
Frequently Asked Questions about HCS01.1E-W0054-A-03-A-CC-EC-EC-S4-NN-FW:
Q: What communication interface is available on the HCS01.1E-W0054-A-03-A-CC-EC-EC-S4-NN-FW drive controller?
A: The HCS01.1E-W0054-A-03-A-CC-EC-EC-S4-NN-FW provides a SERCOS III master communication interface with cross communication capability.
Q: How is the HCS01.1E-W0054-A-03-A-CC-EC-EC-S4-NN-FW cooled during operation?
A: This drive controller uses air cooling via an integrated internal blower for temperature management.
Q: What is the device peak current rating for the HCS01.1E-W0054-A-03-A-CC-EC-EC-S4-NN-FW?
A: The device supports a peak current of 54 A, allowing for high-power operation cycles.
Q: Which encoder protocols are supported by the HCS01.1E-W0054-A-03-A-CC-EC-EC-S4-NN-FW controller's interfaces?
A: Both encoder Interface 1 and Interface 2 on this model support IndraDyn Hiperface and EnDat 2.1/2.2 protocols.
Q: What is the acceptable mains voltage range for the HCS01.1E-W0054-A-03-A-CC-EC-EC-S4-NN-FW drive controller?
A: The HCS01.1E-W0054-A-03-A-CC-EC-EC-S4-NN-FW operates on a mains voltage of 3 x AC 200 to 500 V ±10%.