4.95 based on 202 reviews

🙶 a+ fast delivery 🙷

HCS01.1E-W0054-A-03-A-CC-EC-EC-NN-NN-FW Bosch Rexroth Indramat

MPN: R911338314

No Tariffs On US Orders
  • Rated 4.7 (30 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
Available, Ships in 1-2 weeks

Preparing your secure checkout page...

The Bosch Rexroth Indramat HCS01.1E-W0054-A-03-A-CC-EC-EC-NN-NN-FW is an HCS Drive Controller from the HCS IndraDrive Controllers series. It features a peak current of 54 Amps, is rated for 3-phase AC mains voltage from 200 to 500 Volts, and has IP20 protection. The controller is designed with advanced control sections and supports SERCOS III master cross communication and IndraDyn Hiperface and EnDat 2.1/2.2 encoder interfaces.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The HCS01.1E-W0054-A-03-A-CC-EC-EC-NN-NN-FW is a drive controller produced by Bosch Rexroth Indramat as part of the HCS IndraDrive Controllers series. It supplies regulated power to servo axes and interprets encoder feedback. It also exchanges motion commands with higher-level automation so packaging stations, handling robots, or tooling spindles follow precise speed and torque profiles. Its control architecture supports closed-loop motion in systems that require repeatable response during changing load conditions.

This unit links to neighboring drives and the machine PLC through the SERCOS III master interface, a deterministic Ethernet layer that carries position data and synchronization telegrams. The control section is classified as ADVANCED, which supports extended motion functions such as cross-communication and gantry coupling. Heat is removed by internal air cooling generated by an integrated blower, allowing cabinet installation without external ducting. A device peak current of 54 A lets the inverter handle short-term acceleration demands without saturation. The permissible mains window of 3 x AC 200...500 V ±10% covers common low- and medium-voltage factory networks used worldwide.

The housing carries an IP20 rating, so the unit is intended for protected electrical enclosures rather than direct exposure to dust or liquids. Hardware is released as Design Version 1. The power section supports infeeding and fed operation, allowing the drive to share a common DC bus with companion units during braking or acceleration cycles. Motor feedback arrives on two identical ports that accept IndraDyn Hiperface or EnDat 2.1/2.2 encoder signals, giving the axis high-resolution position data without extra adapter cards. Functional safety is not built in, so any required safety functions must be provided by external devices.

Communication Interface
SERCOS III master (cross communication)
Control Section Design Type
ADVANCED
Cooling Method
Air, internal (through integrated blower)
Design Version
1
Device Peak Current
54 A
Firmware Order Note
Firmware must be ordered as separate sub position
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Interface 2 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
IP Rating
IP20
Line Series
HCS01
Mains Voltage
3 x AC 200...500 V ±10%
Other Design Features
None
Pairing Note
Paired with Control Section Design 'ADVANCED' (A)
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
Safety Interface
Not equipped
  • HCS011EW0054A03ACCECECNNNNFW
  • HCS01 1E W0054 A 03 A CC EC EC NN NN FW
  • hcs01.1e-w0028-a-03-b-et-ec-ec-l3-nn-fw
  • HCS1.1E-W0054-A-03-A-CC-EC-EC-NN-NN-FW

Frequently Asked Questions about HCS01.1E-W0054-A-03-A-CC-EC-EC-NN-NN-FW:

Q: What type of communication interface is available on the HCS01.1E-W0054-A-03-A-CC-EC-EC-NN-NN-FW controller?

A: The HCS01.1E-W0054-A-03-A-CC-EC-EC-NN-NN-FW controller features a SERCOS III master communication interface for cross communication tasks.

Q: What is the peak current capacity of the HCS01.1E-W0054-A-03-A-CC-EC-EC-NN-NN-FW?

A: This drive controller can handle a device peak current of up to 54 A.

Q: How is the HCS01.1E-W0054-A-03-A-CC-EC-EC-NN-NN-FW cooled during operation?

A: Cooling is provided by an internal blower, allowing air-based thermal management.

Q: What mains voltage range does the HCS01.1E-W0054-A-03-A-CC-EC-EC-NN-NN-FW support?

A: The HCS01.1E-W0054-A-03-A-CC-EC-EC-NN-NN-FW requires a three-phase AC supply of 200 to 500 V with ±10% tolerance.

Q: What encoder interfaces are provided by the HCS01.1E-W0054-A-03-A-CC-EC-EC-NN-NN-FW drive controller?

A: It offers encoder interfaces compatible with IndraDyn, Hiperface, and EnDat 2.1/2.2 standards.


Internal Product Review

  • ‘‘The HCS01.1E-W0054-A-03-A-CC-EC-EC-NN-NN-FW from the HCS IndraDrive Controllers line is an advanced drive controller featuring a peak current of 54 A and an IP20 protection rating. Its integrated internal air blower provides efficient cooling, and the SERCOS III master interface enables seamless cross-communication in automation environments. This drive controller stands out for reliable operation in demanding industrial applications.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo