HCS01.1E-W0054-A-03-A-CC-EC-EC-L3-NN-FW Bosch Rexroth Indramat
MPN: R911340725
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The Bosch Rexroth Indramat HCS01.1E-W0054-A-03-A-CC-EC-EC-L3-NN-FW is part of the HCS IndraDrive Controllers series and is designed with an ADVANCED control section paired with a device peak current of 54 Amps. This drive controller features SERCOS III master communication, dual encoder interfaces for IndraDyn Hiperface and EnDat 2.1/2.2, and an IP20 rating. Air cooling is achieved through its integrated blower, and it supports mains voltages from 200 to 500 Volts AC. Safe Torque Off is included as a safety interface.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The HCS01.1E-W0054-A-03-A-CC-EC-EC-L3-NN-FW is a drive controller manufactured by Bosch Rexroth Indramat for the HCS IndraDrive Controllers series. It regulates servo and spindle axes in automated machinery by converting incoming three-phase power into controlled output for synchronous and induction motors. That regulated output allows connected motors to follow commanded torque, speed, and position values during indexing, spindle control, and synchronized machine movement. In an automation cell, the drive handles closed-loop tasks such as torque limiting, speed regulation, and coordinated motion while working with machine-specific PLC or CNC control architectures.
This controller accepts a mains supply of 3 x AC 200 to 500 V ±10%, so one unit can operate across both lower and higher industrial voltage ranges within the stated tolerance. Its peak current of 54 A provides short-term overload capacity for rapid acceleration of medium-frame motors and responsive axis movement during changing load conditions. Communication is handled through a SERCOS III master interface, which supports deterministic data exchange and cross-communication between multiple axes in synchronized systems. The controller has an IP20 housing for protected cabinet installation, and heat is removed by internal air cooling through an integrated blower without the need for external ducting.
The ADVANCED control section provides cycle-synchronous processing for the HCS01 power stage during demanding motion control tasks. Safety is handled through STO, which disables torque at the output stage without disconnecting the mains supply. Dual feedback sockets support IndraDyn Hiperface and EnDat 2.1/2.2 encoders for high-resolution position data, accurate commutation, and stable closed-loop feedback. The power module is rated for infeeding and fed operation, allowing regenerated energy to return to the DC bus during deceleration and other braking events.
Frequently Asked Questions about HCS01.1E-W0054-A-03-A-CC-EC-EC-L3-NN-FW:
Q: What communication interface is available on the HCS01.1E-W0054-A-03-A-CC-EC-EC-L3-NN-FW drive controller?
A: The HCS01.1E-W0054-A-03-A-CC-EC-EC-L3-NN-FW features a SERCOS III master communication interface that enables cross communication with other devices.
Q: How does the HCS01.1E-W0054-A-03-A-CC-EC-EC-L3-NN-FW manage cooling during operation?
A: This controller uses an internal air cooling system with an integrated blower to maintain operational temperatures.
Q: What is the peak current handling capability of the HCS01.1E-W0054-A-03-A-CC-EC-EC-L3-NN-FW?
A: A peak device current of 54 A is supported by the HCS01.1E-W0054-A-03-A-CC-EC-EC-L3-NN-FW.
Q: What types of encoder connections are supported on the HCS01.1E-W0054-A-03-A-CC-EC-EC-L3-NN-FW?
A: The controller provides two encoder interfaces compatible with IndraDyn Hiperface and EnDat 2.1/2.2 encoders.
Q: What safety interface does the HCS01.1E-W0054-A-03-A-CC-EC-EC-L3-NN-FW offer?
A: It is equipped with an STO (Safe Torque Off) safety interface to help ensure safe operation of connected machinery.