HCS01.1E-W0028-A-03-B-ET-EC-PB-NN-NN-FW Bosch Rexroth Indramat
MPN: R911327326
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The Bosch Rexroth Indramat HCS01.1E-W0028-A-03-B-ET-EC-PB-NN-NN-FW is part of the HCS IndraDrive Controllers series. This drive controller features a MultiEthernet communication interface, a device peak current of 28 Amps, and an IP20 rating. It uses internal air cooling with an integrated blower and supports PROFIBUS and encoder interfaces such as IndraDyn Hiperface and EnDat 2.1/2.2.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The HCS01.1E-W0028-A-03-B-ET-EC-PB-NN-NN-FW drive controller is produced by Bosch Rexroth Indramat for the HCS IndraDrive Controllers series. It supplies closed-loop motor regulation, manages axis synchronization, and routes power to connected servomotors inside automated assembly stations and conveyor modules. By combining power electronics with programmable control in a single housing, the unit saves panel space and supports deterministic motion performance on compact equipment. The device also provides bus communication so diagnostic data, status words, and parameter sets can be exchanged with higher-level PLC systems during production.
Its power stage is dimensioned for a device peak current of 28 A, allowing short-term torque surges during acceleration without triggering overcurrent trips. The controller accepts incoming mains within 3 x AC 200 to 500 V ±10%, so it can operate on both 230 V and 400 V factory grids. Thermal management relies on internal air cooling, and the embedded fan channels cabinet air across the heat sink without external ducting. Component protection corresponds to IP20, which permits installation inside a ventilated enclosure while helping prevent accidental finger contact with live parts. Field communication runs on MultiEthernet, providing access for EtherNet/IP, PROFINET, and Modbus TCP masters that exchange commands and diagnostics in real time.
Axis feedback is routed through the Encoder IndraDyn Hiperface/EnDat 2.1/2.2 interface, giving high-resolution position data to the drive processor. Where cell controllers still use cyclic telegrams, the onboard PROFIBUS interface maintains deterministic data exchange without external gateways. Regenerative energy is processed by the infeeding and feed-in power supply concept, so excess DC-link voltage can be shared across the drive group instead of being dissipated as heat. Application logic resides in the BASIC control section. This hardware generation does not include a safety interface.
Frequently Asked Questions about HCS01.1E-W0028-A-03-B-ET-EC-PB-NN-NN-FW:
Q: What communication interface is used by the HCS01.1E-W0028-A-03-B-ET-EC-PB-NN-NN-FW controller?
A: The HCS01.1E-W0028-A-03-B-ET-EC-PB-NN-NN-FW supports MultiEthernet communication for connectivity.
Q: What is the peak current of the HCS01.1E-W0028-A-03-B-ET-EC-PB-NN-NN-FW drive controller?
A: This drive controller has a peak current capacity of 28 A.
Q: How is the HCS01.1E-W0028-A-03-B-ET-EC-PB-NN-NN-FW drive controller cooled?
A: The HCS01.1E-W0028-A-03-B-ET-EC-PB-NN-NN-FW uses internal air cooling through an integrated blower.
Q: What is the mains voltage range for the HCS01.1E-W0028-A-03-B-ET-EC-PB-NN-NN-FW controller?
A: The HCS01.1E-W0028-A-03-B-ET-EC-PB-NN-NN-FW operates with a mains voltage supply of 3 x AC 200 to 500 V ±10%.
Q: What is the IP rating for the HCS01.1E-W0028-A-03-B-ET-EC-PB-NN-NN-FW drive controller?
A: This controller features an IP20 enclosure rating, providing basic protection against solid objects.