The Bosch Rexroth Indramat HCS01.1E-W0028-A-03-B-ET-EC-NN-SB-NN-FW is part of the HCS IndraDrive Controllers series. This HCS drive controller uses an internal air cooling method with an integrated blower and supports a MultiEthernet communication interface. It has a device peak current of 28 Amps, is rated at IP20, and operates with a mains voltage of 3 x AC 200 to 500 Volts.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The HCS01.1E-W0028-A-03-B-ET-EC-NN-SB-NN-FW is a drive controller produced by Bosch Rexroth Indramat for the HCS IndraDrive Controllers series. It converts three-phase AC supply power into regulated motor voltages while executing motion commands generated by higher-level PLCs. Within automated production cells, the unit coordinates speed and torque loops for axes such as pick-and-place gantries, feeders, and conveyor segments. Its integrated control and power electronics reduce panel space and simplify cabinet wiring for compact axis control when compared with discrete amplifier architectures.
For electrical integration, the controller accepts a supply of 3 x AC 200...500 V ±10%, allowing operation on a broad range of plant voltages. The power stage can deliver up to 28 A of peak output current, giving machines sufficient short-term torque for rapid acceleration or braking events. Networked control is handled through a MultiEthernet interface that supports PROFINET, EtherNet/IP, and additional protocol selections in one port. Motor feedback connects through an IndraDyn Hiperface and EnDat 2.1/2.2 encoder interface for high-resolution position data, enabling tight servo loops. Cabinet installation is simplified by the drive’s IP20 housing, which provides finger-safe protection without requiring a gasketed enclosure.
The control section fitted to this module is the BASIC variant, paired at the factory to match the power stage and feature set. Thermal management relies on internal air cooling through an integrated blower, so external ducting or liquid loops are unnecessary. DC bus energy is exchanged through an infeeding and power-sharing supply scheme, which lets adjacent axes share regenerated power in multi-axis systems. The compact frame coded HCS01 is the smallest mechanical size in the line, and Interface 2 remains unequipped for option cards.
Frequently Asked Questions about HCS01.1E-W0028-A-03-B-ET-EC-NN-SB-NN-FW:
Q: What type of communication interface does the HCS01.1E-W0028-A-03-B-ET-EC-NN-SB-NN-FW support?
A: The HCS01.1E-W0028-A-03-B-ET-EC-NN-SB-NN-FW controller features a MultiEthernet communication interface for flexible network integration.
Q: How is the HCS01.1E-W0028-A-03-B-ET-EC-NN-SB-NN-FW cooled?
A: This drive controller uses an internal air cooling system with an integrated blower for temperature management.
Q: What is the peak current rating of the HCS01.1E-W0028-A-03-B-ET-EC-NN-SB-NN-FW?
A: The maximum device peak current for this IndraDrive controller is 28 A.
Q: What level of ingress protection does the HCS01.1E-W0028-A-03-B-ET-EC-NN-SB-NN-FW offer?
A: The HCS01.1E-W0028-A-03-B-ET-EC-NN-SB-NN-FW has an IP20 rating, meaning it is protected against solid objects larger than 12.5 mm.
Q: Which encoder interfaces are available on the HCS01.1E-W0028-A-03-B-ET-EC-NN-SB-NN-FW controller?
A: The first interface supports Encoder IndraDyn Hiperface and EnDat 2.1/2.2 connections.