4.95 based on 202 reviews

🙶 Great service, they have the parts i needed in stock. 🙷

HCS01.1E-W0028-A-03-B-ET-EC-NN-S5-NN-FW Bosch Rexroth Indramat

MPN: R911376620

No Tariffs On US Orders
  • Rated 4.5 (43 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
In-Stock, Ships 3-5 Days

Preparing your secure checkout page...

The Bosch Rexroth Indramat HCS01.1E-W0028-A-03-B-ET-EC-NN-S5-NN-FW is part of the HCS IndraDrive Controllers series and features a MultiEthernet communication interface. This drive controller supports a peak current of 28 Amps and operates with a mains voltage of 3 x AC 200 to 500 Volts. The cooling method is air through an internal integrated blower and it has an IP20 rating.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The HCS01.1E-W0028-A-03-B-ET-EC-NN-S5-NN-FW is a drive controller manufactured by Bosch Rexroth Indramat for the HCS IndraDrive Controllers series. Installed in control cabinets, it bridges the plant power bus and the servo axes, converting line energy into regulated DC while executing motion commands issued by a matching control section. By combining its power stage with modular electronics, it enables flexible integration of servo or spindle motors into automated assembly cells, packaging lines, and material-handling equipment.

The power stage accepts a three-phase supply of 3 × AC 200…500 V ±10%, allowing the same unit to run on 230 V or 480 V factory networks without hardware changes. For short acceleration bursts, it can deliver a peak output current of 28 A, which sets the maximum short-term motor demand during rapid indexing. A MultiEthernet port supports real-time traffic over PROFINET, EtherNet/IP, or EtherCAT, so the controller can exchange commands directly with modern PLCs. Internal thermal management relies on internal air cooling through an integrated blower; the blower moves cabinet air across the heat sink and eliminates the need for external ducting. With an enclosure rating of IP20, live parts are finger-safe, but the device must be mounted in a protected enclosure where ambient dust and moisture are controlled.

The installed control card uses the BASIC design, providing standard drive functions without advanced safety or I/O extensions and matching the pairing note for this model. The unit is Design version 1. The integrated power supply uses infeeding and fed operation, meaning it can share a common DC bus with other drives and return braking energy. For position feedback, interface 1 supports IndraDyn Hiperface and EnDat 2.1/2.2 encoders, while the second encoder slot is unused.

Communication Interface
MultiEthernet
Control Section Design Type
BASIC
Cooling Method
Air, internal (through integrated blower)
Design Version
1
Device Peak Current
28 A
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Interface 2 Type
Not equipped
IP Rating
IP20
Line Series
HCS01
Mains Voltage
3 x AC 200...500 V ±10%
Other Design Features
None
Pairing Note
Paired with Control Section Design 'BASIC' (B)
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
  • HCS011EW0028A03BETECNNS5NNFW
  • HCS01 1E W0028 A 03 B ET EC NN S5 NN FW
  • hcs01.1e-w0028-a-03-a-et-ec-da-nn-nn-fw
  • HCS1.1E-W0028-A-03-B-ET-EC-NN-S5-NN-FW

Frequently Asked Questions about HCS01.1E-W0028-A-03-B-ET-EC-NN-S5-NN-FW:

Q: What communication interface is available on the HCS01.1E-W0028-A-03-B-ET-EC-NN-S5-NN-FW drive controller?

A: The HCS01.1E-W0028-A-03-B-ET-EC-NN-S5-NN-FW supports MultiEthernet as its main communication interface.

Q: What is the peak current supported by the HCS01.1E-W0028-A-03-B-ET-EC-NN-S5-NN-FW?

A: This drive controller has a peak current rating of 28 A.

Q: What cooling method does the HCS01.1E-W0028-A-03-B-ET-EC-NN-S5-NN-FW utilize?

A: Air cooling is used internally through an integrated blower.

Q: What IP rating does the HCS01.1E-W0028-A-03-B-ET-EC-NN-S5-NN-FW have?

A: The HCS01.1E-W0028-A-03-B-ET-EC-NN-S5-NN-FW has an IP20 rating, which indicates limited ingress protection.

Q: What mains voltage range can the HCS01.1E-W0028-A-03-B-ET-EC-NN-S5-NN-FW operate on?

A: This controller operates with a mains voltage of 3 x AC 200 to 500 V ±10%.


Internal Product Review

  • ‘‘The HCS01.1E-W0028-A-03-B-ET-EC-NN-S5-NN-FW is a Bosch Rexroth Indramat HCS drive controller with MultiEthernet communication and a BASIC control section. Internal air cooling through an integrated blower and IP20 protection support dependable cabinet operation in standard industrial environments. A 28 A peak current rating with 3 x AC 200...500 V input marks the controller as a highly capable IndraDrive option.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo