HCS01.1E-W0028-A-03-B-ET-EC-NN-S4-NN-NW Bosch Rexroth Indramat
MPN: R911379382
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
Current response time:
3 Minutes
7 Seconds
The Bosch Rexroth Indramat HCS01.1E-W0028-A-03-B-ET-EC-NN-S4-NN-NW is part of the HCS IndraDrive Controllers series and features a MultiEthernet communication interface. This drive controller has a device peak current of 28 Amps and supports encoder interfaces such as IndraDyn Hiperface and EnDat 2.1/2.2. It uses an integrated blower for air cooling and has an IP20 protection rating.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The HCS01.1E-W0028-A-03-B-ET-EC-NN-S4-NN-NW is a drive controller manufactured by Bosch Rexroth Indramat within the HCS IndraDrive Controllers series. Installed in a cabinet, it links the plant power network to servo or induction motors while coordinating motion commands issued by a PLC. The device belongs to the HCS01 line and is classified as an HCS drive controller, indicating its role in regulating motor torque, velocity, and position for automated handling, packaging, and processing equipment.
This controller communicates with supervisory systems through MultiEthernet, allowing Profinet, EtherNet/IP, and EtherCAT protocols to be selected in software without hardware changes. It accepts a mains supply of 3 × AC 200…500 V ±10%, so a wide range of three-phase plant voltages can be used without an external transformer. During rapid acceleration or braking sequences, the power stage can deliver a device peak current of 28 A, giving headroom above the continuous rating for short load surges. Internal temperature is managed by internal air cooling through an integrated blower that draws cabinet air across the heat sink, and no external ducting is required. An enclosure rating of IP20 classifies the unit for installation inside a protected electrical enclosure where solid objects larger than 12 mm are excluded, but no water protection is provided.
The control section fitted to this model is the BASIC design, which provides standard drive functionality without advanced technology options. The unit is design version 1, and accessories must match this release. Motor feedback is processed through the multifunction IndraDyn Hiperface/EnDat 2.1/2.2 encoder interface, enabling high-resolution position data for synchronous axes. Power is shared on the DC bus using an infeeding and fed supply concept, allowing regenerative energy from one axis to be used by others or returned to the grid. The secondary interface slot is not equipped, leaving space available for future expansion.
Frequently Asked Questions about HCS01.1E-W0028-A-03-B-ET-EC-NN-S4-NN-NW:
Q: What communication interface does the HCS01.1E-W0028-A-03-B-ET-EC-NN-S4-NN-NW use?
A: This controller supports MultiEthernet for versatile connectivity.
Q: What is the device’s peak current for the HCS01.1E-W0028-A-03-B-ET-EC-NN-S4-NN-NW?
A: The controller offers a peak current output of 28 A.
Q: How is the HCS01.1E-W0028-A-03-B-ET-EC-NN-S4-NN-NW cooled?
A: Cooling is handled internally using an integrated blower.
Q: What mains voltage does the HCS01.1E-W0028-A-03-B-ET-EC-NN-S4-NN-NW support?
A: The power input requires a 3-phase AC supply of 200 to 500 V ±10%.
Q: Which encoder interface types are available on this drive controller?
A: The controller is equipped with an encoder interface supporting IndraDyn Hiperface and EnDat 2.1/2.2.