4.95 based on 202 reviews

🙶 First-time customer with Wake Industrial. The ordering process was completely seamless. The part that we o... 🙷

HCS01.1E-W0028-A-03-B-ET-EC-NN-S4-NN-FW Bosch Rexroth Indramat

MPN: R911340084

No Tariffs On US Orders
  • Rated 4.5 (38 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
In-Stock, Ships 3-5 Days

Preparing your secure checkout page...

The Bosch Rexroth Indramat HCS01.1E-W0028-A-03-B-ET-EC-NN-S4-NN-FW is a drive controller from the HCS IndraDrive Controllers series. It features a MultiEthernet communication interface and an internal air cooling system with an integrated blower. This unit has a peak current of 28 Amps and supports encoder interfaces such as IndraDyn Hiperface and EnDat 2.1/2.2.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The HCS01.1E-W0028-A-03-B-ET-EC-NN-S4-NN-FW drive controller is manufactured by Bosch Rexroth Indramat and belongs to the HCS IndraDrive Controllers series. It functions as the power and control interface between a three-phase mains supply and synchronous or induction motors, executing closed-loop speed and torque regulation for automated assembly cells, packaging lines, and handling systems. Within an IndraDrive installation, it occupies the converter slot, receives commands from a higher-level PLC, and delivers regulated current to the connected axes.

A multi-protocol Ethernet port provides system networking through the MultiEthernet communication interface, allowing real-time exchange over SERCOS III, EtherNet/IP, or PROFINET without additional hardware. The mains input range is 3 x AC 200...500 V ±10%, so one unit can operate across common industrial supply levels. Peak output capability reaches 28 A, giving current margin for acceleration and brief overload events. Thermal management uses internal air cooling through an integrated blower, which directs cabinet air across the heat sink without external ducting. For electrical safety, the housing has an IP20 rating, so it is finger-safe and intended for installation inside a control cabinet.

The unit uses the BASIC control section type, which suits general-purpose motion tasks while keeping the footprint compact. Feedback wiring is accepted through a multifunction encoder port with IndraDyn encoder support for Hiperface and EnDat 2.1/2.2, allowing absolute position capture for compatible motors. Within the broader family, it is classified under the line designation HCS01, which indicates the mechanical dimensions and cooling arrangement. The power interface supports infeeding or fed operation, so the module can either supply DC bus energy to neighboring drives or draw from an existing DC link. Design version 1 and an unpopulated Interface 2 slot leave room for later functional expansion without rewiring.

Communication Interface
MultiEthernet
Control Section Design Type
BASIC
Cooling Method
Air, internal (through integrated blower)
Design Version
1
Device Peak Current
28 A
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Interface 2 Type
Not equipped
IP Rating
IP20
Line Series
HCS01
Mains Voltage
3 x AC 200...500 V ±10%
Other Design Features
None
Pairing Note
Paired with Control Section Design 'BASIC' (B)
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
  • HCS011EW0028A03BETECNNS4NNFW
  • HCS01 1E W0028 A 03 B ET EC NN S4 NN FW
  • hcs01.1e-w0028-a-03-a-cc-ec-pb-s4-nn-fw
  • HCS1.1E-W0028-A-03-B-ET-EC-NN-S4-NN-FW

Frequently Asked Questions about HCS01.1E-W0028-A-03-B-ET-EC-NN-S4-NN-FW:

Q: What communication interface is available on the HCS01.1E-W0028-A-03-B-ET-EC-NN-S4-NN-FW?

A: This drive controller features a MultiEthernet communication interface for flexible connectivity options.

Q: What is the peak current rating of the HCS01.1E-W0028-A-03-B-ET-EC-NN-S4-NN-FW?

A: The device supports a peak current of 28 A for demanding drive applications.

Q: What cooling method is employed in the HCS01.1E-W0028-A-03-B-ET-EC-NN-S4-NN-FW controller?

A: This model uses an integrated blower for internal air cooling.

Q: Which encoder protocols are compatible with the primary interface of the HCS01.1E-W0028-A-03-B-ET-EC-NN-S4-NN-FW?

A: The main encoder interface supports IndraDyn, Hiperface, and EnDat 2.1/2.2 encoders.

Q: What IP rating does the HCS01.1E-W0028-A-03-B-ET-EC-NN-S4-NN-FW have?

A: This drive controller is rated at IP20, indicating basic protection against solid objects.


Internal Product Review

  • ‘‘The HCS01.1E-W0028-A-03-B-ET-EC-NN-S4-NN-FW is an HCS drive controller featuring MultiEthernet communication and a BASIC control section design. Internal air cooling through an integrated blower supports stable thermal management, while IP20 protection fits enclosed industrial cabinet applications. A 28 A peak current and 3 x AC 200 to 500 V mains range make this unit a highly capable choice for demanding motion control service.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo