4.95 based on 202 reviews

🙶 Product was as advertised, got the machine back up and running at a fraction of OEM price. Delivered on ti... 🙷

HCS01.1E-W0028-A-03-B-ET-EC-EM-S4-NN-AW Bosch Rexroth Indramat

MPN: R911397671

No Tariffs On US Orders
  • Rated 4.4 (31 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
Ask for Availability

Preparing your secure checkout page...

The Bosch Rexroth Indramat HCS01.1E-W0028-A-03-B-ET-EC-EM-S4-NN-AW is a drive controller from the HCS IndraDrive Controllers series. It has a MultiEthernet communication interface and an internal air cooling method through an integrated blower. This controller supports encoder interfaces such as IndraDyn Hiperface and EnDat 2.1/2.2, and operates with a peak current of 28 Amps at a mains voltage of 3 x AC 200 to 500 Volts.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The HCS01.1E-W0028-A-03-B-ET-EC-EM-S4-NN-AW is a drive controller manufactured by Bosch Rexroth Indramat as part of the HCS IndraDrive Controllers series. The unit regulates three-phase servo or induction motors in automation cells, acting as the power stage that converts plant mains into controlled motor current. It belongs to the compact HCS01 hardware line and pairs with a control section to support motion control, diagnostics, and fieldbus communication. Its compact format also suits dense cabinet layouts used in packaging, handling, and general automation equipment.

The controller accepts a supply of 3 x AC 200 to 500 V ±10%, allowing the same hardware to operate on both 230 V and 400 V networks without tap changes. Peak output capability reaches 28 A, so short acceleration bursts can be delivered without adding external choppers. Internal thermal management uses internal air cooling through an integrated blower, and the blower circulates cabinet air across the heat sink to maintain rated current at 45 °C ambient. For plant networking, the controller hosts a MultiEthernet interface, and the backplane auto-negotiates Sercos III, EtherNet/IP, EtherCAT, and PROFINET protocols. The housing carries an IP20 rating, so it is finger-safe but intended for installation inside a control cabinet.

The controller is delivered in design version 1, which matches the initial release of this platform. Encoder feedback is handled through two dedicated ports: Interface 1 accepts IndraDyn Hiperface or EnDat 2.1/2.2 encoder signals for absolute position data, while Interface 2 provides encoder emulation pulses for legacy drives. The control section specified as BASIC supports single-axis positioning and includes a local USB port for service access. The converter supports infeeding or fed operation, so it can receive energy from an upstream supply module or return energy to the DC bus during regeneration.

Communication Interface
MultiEthernet
Control Section Design Type
BASIC
Cooling Method
Air, internal (through integrated blower)
Design Version
1
Device Peak Current
28 A
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Interface 2 Type
Encoder emulation
IP Rating
IP20
Line Series
HCS01
Mains Voltage
3 x AC 200...500 V ±10%
Other Design Features
None
Pairing Note
Paired with Control Section Design 'BASIC' (B)
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
  • HCS011EW0028A03BETECEMS4NNAW
  • HCS01 1E W0028 A 03 B ET EC EM S4 NN AW
  • hcs01.1e-w0028-a-03-a-cc-ec-cn-nn-nn-fw
  • HCS1.1E-W0028-A-03-B-ET-EC-EM-S4-NN-AW

Frequently Asked Questions about HCS01.1E-W0028-A-03-B-ET-EC-EM-S4-NN-AW:

Q: What type of communication interface is available on the HCS01.1E-W0028-A-03-B-ET-EC-EM-S4-NN-AW?

A: This model supports MultiEthernet for flexible communication and connectivity.

Q: How is the HCS01.1E-W0028-A-03-B-ET-EC-EM-S4-NN-AW drive controller cooled?

A: Cooling is handled by an internal air system with an integrated blower.

Q: What is the device peak current for the HCS01.1E-W0028-A-03-B-ET-EC-EM-S4-NN-AW?

A: The peak current for this drive controller is rated at 28 A.

Q: What mains voltage range does this drive controller support?

A: The HCS01.1E-W0028-A-03-B-ET-EC-EM-S4-NN-AW operates at 3 x AC 200...500 V ±10%.

Q: Which encoder interface is featured as Interface 1 on the HCS01.1E-W0028-A-03-B-ET-EC-EM-S4-NN-AW?

A: This controller uses the IndraDyn Hiperface/EnDat 2.1/2.2 as its primary encoder interface.


Internal Product Review

  • ‘‘The HCS01.1E-W0028-A-03-B-ET-EC-EM-S4-NN-AW is a Bosch Rexroth Indramat HCS IndraDrive controller featuring MultiEthernet communication and a BASIC control section. Its internal air cooling with an integrated blower and 28 A peak current support efficient operation in demanding environments. The IP20 rating and encoder compatibility make this drive controller a solid choice for advanced automation systems.’’