4.95 based on 202 reviews

🙶 Easy to navigate website and quick responses from support. Additionally, pretty fast shipping. Our mainte... 🙷

HCS01.1E-W0028-A-03-B-ET-EC-EC-S4-NN-FW Bosch Rexroth Indramat

MPN: R911340082

No Tariffs On US Orders
  • Rated 4.5 (43 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
Ask for Availability

Preparing your secure checkout page...

The Bosch Rexroth Indramat HCS01.1E-W0028-A-03-B-ET-EC-EC-S4-NN-FW is part of the HCS IndraDrive Controllers series and features a MultiEthernet communication interface. This drive controller has a device peak current of 28 Amps, uses internal air cooling with an integrated blower, and is rated IP20. It supports encoder interfaces such as IndraDyn Hiperface and EnDat 2.1/2.2, and operates with a mains voltage range of 3 x AC 200 to 500 Volts.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The HCS01.1E-W0028-A-03-B-ET-EC-EC-S4-NN-FW is a compact HCS drive controller produced by Bosch Rexroth Indramat within the HCS IndraDrive Controllers series. The unit supplies regulated power and closed-loop control signals to a connected motor, forming a drive axis in an automated machine. By accepting three-phase mains input and exchanging data with a plant network, it carries out speed, torque, and position commands from a higher-level motion control system. This arrangement allows the controller to match motor response to changing process demands during positioning, speed regulation, and torque-controlled movement.

For network integration, the controller provides a MultiEthernet interface that supports common industrial protocols, and this single port allows communication with PLCs and diagnostic tools. Its control section uses the BASIC design, so application functions and parameter memory remain on the main board without optional expansion cards. The power stage accepts 3 x AC 200–500 V mains with a tolerance of ±10%, and the integrated converter can deliver a peak output of 28 A during short acceleration periods. The housing is rated IP20, which helps protect against accidental contact with live parts, and cooling is provided by a built-in air blower that circulates internal air without requiring external ducting in most cabinet layouts.

In this product line, the device is design version 1, indicating the first version of this housing and power section. It uses two encoder channels for IndraDyn Hiperface and EnDat 2.1 / 2.2 feedback, so precise rotor position information is available for closed-loop operation and for connection to compatible motor feedback systems. The power supply is configured for infeeding and fed operation, which allows the drive to receive DC-bus energy from an upstream supply or return regenerated power to the common line. This operating mode suits multi-axis systems that share power across several connected drives.

Communication Interface
MultiEthernet
Control Section Design Type
BASIC
Cooling Method
Air, internal (through integrated blower)
Design Version
1
Device Peak Current
28 A
Firmware Order Note
Firmware must be ordered as separate sub position
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Interface 2 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
IP Rating
IP20
Line Series
HCS01
Mains Voltage
3 x AC 200...500 V ±10%
Other Design Features
None
Pairing Note
Paired with Control Section Design 'BASIC' (B)
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
  • HCS011EW0028A03BETECECS4NNFW
  • HCS01 1E W0028 A 03 B ET EC EC S4 NN FW
  • hcs01.1e-w0018-a-03-e-s3-ec-nn-l3-nn-fw
  • HCS1.1E-W0028-A-03-B-ET-EC-EC-S4-NN-FW

Frequently Asked Questions about HCS01.1E-W0028-A-03-B-ET-EC-EC-S4-NN-FW:

Q: What cooling method does the HCS01.1E-W0028-A-03-B-ET-EC-EC-S4-NN-FW use?

A: This drive controller uses an internal air cooling system with an integrated blower.

Q: What communication interface is available on the HCS01.1E-W0028-A-03-B-ET-EC-EC-S4-NN-FW?

A: The HCS01.1E-W0028-A-03-B-ET-EC-EC-S4-NN-FW supports a MultiEthernet communication interface.

Q: What is the peak current for the HCS01.1E-W0028-A-03-B-ET-EC-EC-S4-NN-FW drive controller?

A: This model provides a device peak current of 28 A.

Q: What mains voltage range is supported by the HCS01.1E-W0028-A-03-B-ET-EC-EC-S4-NN-FW?

A: The controller is rated for a mains voltage of 3 x AC 200 to 500 V ±10%.

Q: What encoder interface types are present on the HCS01.1E-W0028-A-03-B-ET-EC-EC-S4-NN-FW drive controller?

A: The HCS01.1E-W0028-A-03-B-ET-EC-EC-S4-NN-FW provides two encoder interfaces compatible with IndraDyn Hiperface and EnDat 2.1/2.2.


Internal Product Review

  • ‘‘The HCS01.1E-W0028-A-03-B-ET-EC-EC-S4-NN-FW is a high-quality drive controller from the Bosch Rexroth IndraDrive series, designed for applications requiring MultiEthernet communication and a BASIC control section. Its internal air cooling with an integrated blower ensures reliable thermal management, while a peak current rating of 28 A supports demanding motion control tasks. The controller stands out for its IP20 rating and versatile encoder interface compatibility, making it a dependable choice for modern automation systems.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo