The Bosch Rexroth Indramat HCS01.1E-W0028-A-03-B-ET-EC-EC-L2-NN-FW is an HCS Drive Controller in the HCS IndraDrive Controllers series with a device peak current of 28 Amps and an IP20 rating. It features MultiEthernet communication and supports encoder interfaces such as IndraDyn Hiperface and EnDat 2.1/2.2. This controller uses internal air cooling through an integrated blower and operates on a mains voltage of 3 x AC 200 to 500 Volts.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The HCS01.1E-W0028-A-03-B-ET-EC-EC-L2-NN-FW is a compact drive controller produced by Bosch Rexroth Indramat for the HCS IndraDrive Controllers series. Designed for cabinet installation, this unit regulates power delivery between the plant mains and an IndraDyn servo or synchronous motor, enabling closed-loop speed and torque control in automated lines, packaging equipment, and material-handling cells. As part of a modular drive system, the controller houses both power and control electronics in one enclosure, streamlining wiring and maintenance tasks while providing parameterization through the series’ standard tool set.

The controller communicates with supervisory PLCs over MultiEthernet, allowing protocol-selectable integration without additional option cards. Its control section is designated BASIC, meaning the internal processor executes standard motion functions without advanced safety extensions. During acceleration events, the inverter can deliver a device peak current of 28 A, allowing the connected motor to draw higher current for short bursts. The enclosure is rated IP20, so the unit requires mounting inside a closed electrical cabinet. Power is derived from a three-phase supply of 3 × AC 200…500 V ±10 %, a wide range that covers common low- and medium-voltage plant networks.

The drive uses Design Version 1. Feedback from rotary and linear motors is accepted on two identical channels that support Hiperface/EnDat 2.1/2.2, enabling redundant encoder monitoring or dual-loop operation when precise position and velocity signals are required. The unit uses an infeeding / fed power module, so it can share a common DC bus or receive line power independently, depending on cabinet topology. Internal air movement is provided by an integrated blower, eliminating the need for external ducting in this frame size. The control section is matched to the HCS01 mechanical size.

Communication Interface
MultiEthernet
Control Section Design Type
BASIC
Cooling Method
Air, internal (through integrated blower)
Design Version
1
Device Peak Current
28 A
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Interface 2 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
IP Rating
IP20
Line Series
HCS01
Mains Voltage
3 x AC 200...500 V ±10%
Other Design Features
None
Pairing Note
Paired with Control Section Design 'BASIC' (B)
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
  • HCS011EW0028A03BETECECL2NNFW
  • HCS01 1E W0028 A 03 B ET EC EC L2 NN FW
  • hcs01.1e-w0018-a-03-b-et-ec-pb-nn-aa-fw
  • HCS1.1E-W0028-A-03-B-ET-EC-EC-L2-NN-FW

Frequently Asked Questions about HCS01.1E-W0028-A-03-B-ET-EC-EC-L2-NN-FW:

Q: What kind of cooling method does the HCS01.1E-W0028-A-03-B-ET-EC-EC-L2-NN-FW drive controller use?

A: The HCS01.1E-W0028-A-03-B-ET-EC-EC-L2-NN-FW utilizes an internal air cooling system with an integrated blower.

Q: What is the peak current capacity of the HCS01.1E-W0028-A-03-B-ET-EC-EC-L2-NN-FW controller?

A: This model has a peak current capability of 28 A for demanding drive applications.

Q: Which communication interface is available on the HCS01.1E-W0028-A-03-B-ET-EC-EC-L2-NN-FW?

A: The HCS01.1E-W0028-A-03-B-ET-EC-EC-L2-NN-FW supports MultiEthernet connectivity for flexible integration with various network environments.

Q: What is the IP rating of the HCS01.1E-W0028-A-03-B-ET-EC-EC-L2-NN-FW drive controller?

A: The protection rating of this controller is IP20, providing basic protection against solid objects.

Q: Which encoder interface types are supported by this drive controller?

A: Both Interface 1 and Interface 2 support IndraDyn Hiperface or EnDat 2.1/2.2 encoders.


Internal Product Review

  • ‘‘The HCS01.1E-W0028-A-03-B-ET-EC-EC-L2-NN-FW is an HCS drive controller with a BASIC control section and MultiEthernet communication. Internal blower cooling and IP20 protection support dependable cabinet integration in demanding automation systems. A 28 A peak current rating with 3 x AC 200 to 500 V mains input makes the unit a strong choice for flexible drive applications.’’