4.95 based on 202 reviews

🙶 Great service, they have the parts i needed in stock. 🙷

HCS01.1E-W0028-A-03-B-ET-EC-CN-S4-NN-FW Bosch Rexroth Indramat

MPN: R911374836

No Tariffs On US Orders
  • Rated 4.5 (47 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
Ask for Availability

Current response time:
5 Minutes 9 Seconds

Preparing your secure checkout page...

The Bosch Rexroth Indramat HCS01.1E-W0028-A-03-B-ET-EC-CN-S4-NN-FW is a drive controller in the HCS IndraDrive Controllers series. It features a MultiEthernet communication interface and supports CANopen and encoder interfaces such as IndraDyn Hiperface and EnDat 2.1/2.2. The controller uses an internal air cooling method with an integrated blower and has a peak current rating of 28 Amps.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The HCS01.1E-W0028-A-03-B-ET-EC-CN-S4-NN-FW is a drive controller manufactured by Bosch Rexroth Indramat within the HCS IndraDrive Controllers series. It combines a power stage with digital control functions to command servo and induction motors used in material-handling lines, pick-and-place stations, and modular machine tools. By converting incoming three-phase power into regulated output and linking directly to upper-level PLCs, the unit supports compact automation cabinets where drive density and DIN-rail space are critical.

The controller communicates over MultiEthernet, allowing the same hardware to join PROFINET, EtherNet/IP, and EtherCAT networks without option cards. Its control section is specified as BASIC, a configuration that provides standard axis functions while keeping the parameter count moderate. During acceleration events, the power stage can deliver a device peak current of 28 A, and thermal energy is removed by an internal blower that circulates air through the heat sink. The housing carries an IP20 rating, so it is intended for installation inside a closed cabinet. Electrical input spans 3 × AC 200-500 V ±10%, which allows use on both 230 V and 400 V plant supplies.

Axis feedback enters on the dedicated Encoder IndraDyn Hiperface/EnDat 2.1/2.2 port, while decentralized I/O or diagnostic devices can share data through the integrated CANopen bus. The power section uses infeeding and fed operation, enabling connection to common DC bus arrangements that return regenerated energy to the supply. The unit is Design Version 1. The control section is matched to the associated power module in the HCS01 line. This arrangement supports a consistent connection between the control electronics and the power stage during operation.

Communication Interface
MultiEthernet
Control Section Design Type
BASIC
Cooling Method
Air, internal (through integrated blower)
Design Version
1
Device Peak Current
28 A
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Interface 2 Type
CANopen
IP Rating
IP20
Line Series
HCS01
Mains Voltage
3 x AC 200...500 V ±10%
Other Design Features
None
Pairing Note
Paired with Control Section Design 'BASIC' (B)
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
  • HCS011EW0028A03BETECCNS4NNFW
  • HCS01 1E W0028 A 03 B ET EC CN S4 NN FW
  • hcs01.1e-w0018-a-03-b-et-ec-pb-l3-nn-fw
  • HCS1.1E-W0028-A-03-B-ET-EC-CN-S4-NN-FW

Frequently Asked Questions about HCS01.1E-W0028-A-03-B-ET-EC-CN-S4-NN-FW:

Q: What communication interface is available on the HCS01.1E-W0028-A-03-B-ET-EC-CN-S4-NN-FW controller?

A: The HCS01.1E-W0028-A-03-B-ET-EC-CN-S4-NN-FW supports MultiEthernet as its communication interface for network connectivity.

Q: What is the device peak current rating for the HCS01.1E-W0028-A-03-B-ET-EC-CN-S4-NN-FW?

A: This drive controller is designed for a peak current of 28 A, suitable for medium-duty automation tasks.

Q: How is the HCS01.1E-W0028-A-03-B-ET-EC-CN-S4-NN-FW cooled during operation?

A: Cooling is provided by an internal air system utilizing an integrated blower, keeping the unit at optimal temperatures.

Q: What mains voltage does the HCS01.1E-W0028-A-03-B-ET-EC-CN-S4-NN-FW accept?

A: The mains voltage requirement ranges from 3 x AC 200 to 500 V with a tolerance of plus or minus 10%.

Q: What is the IP rating of the HCS01.1E-W0028-A-03-B-ET-EC-CN-S4-NN-FW controller?

A: This model is classified as IP20, which provides protection against solid objects but not against liquids.


Internal Product Review

  • ‘‘The HCS01.1E-W0028-A-03-B-ET-EC-CN-S4-NN-FW is an HCS drive controller with internal air cooling through an integrated blower. MultiEthernet communication and CANopen support make integration straightforward in modern motion systems. IP20 protection and 28 A peak current give the unit a strong balance of cabinet-ready design and responsive drive performance.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo