4.95 based on 202 reviews

🙶 First-time customer with Wake Industrial. The ordering process was completely seamless. The part that we o... 🙷

HCS01.1E-W0028-A-03-A-ET-EC-DA-NN-NN-FW Bosch Rexroth Indramat

MPN: R911373476

No Tariffs On US Orders
  • Rated 4.6 (55 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
In-Stock, Ships 3-5 Days

Preparing your secure checkout page...

The Bosch Rexroth Indramat HCS01.1E-W0028-A-03-A-ET-EC-DA-NN-NN-FW is part of the HCS IndraDrive Controllers series. This drive controller features a MultiEthernet communication interface, supports a device peak current of 28 Amps, and has an IP20 rating. It uses air cooling through an integrated blower and is designed to be paired with the BASIC control section.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The HCS01.1E-W0028-A-03-A-ET-EC-DA-NN-NN-FW belongs to the HCS IndraDrive Controllers series from Bosch Rexroth Indramat. It is a drive controller intended to regulate torque, speed, and position in servo-based automation systems. Within the HCS01 line, it serves as the power section, while a BASIC control section handles higher-level logic. This arrangement separates motion control tasks from the power electronics and supports modular cabinet layouts. The unit fits into IP20 control cabinets and connects to an external infeeding module for DC-bus energy management.

This controller accepts a three-phase supply of 3 × AC 200…500 V ±10% and uses MultiEthernet to exchange real-time data with PLCs and SCADA layers. This network connection supports deterministic communication between the drive, the machine controller, and the supervisory interface. Thermal management relies on internal air cooling through an integrated blower, eliminating the need for external ducting. A device peak current of 28 A is available for acceleration or short overload events, while continuous current depends on cabinet temperature and wiring. The housing carries an IP20 rating, so all live parts must be mounted behind protective covers.

An encoder interface that supports IndraDyn Hiperface / EnDat 2.1 / 2.2 feedback enables high-resolution position control without additional option cards. It also allows the controller to work with common motor feedback devices used on the platform. Power is delivered on a shared DC bus, allowing energy to be exchanged among multiple axes. The module is identified as design version 1, which corresponds to its mechanical footprint and connector layout. The drive is without an integrated safety interface, so any required stop functions must be handled by external safety relays or controllers. The BASIC control section pairing keeps the drive matched to compatible control hardware.

Communication Interface
MultiEthernet
Cooling Method
Air, internal (through integrated blower)
Design Version
1
Device Peak Current
28 A
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
IP Rating
IP20
Line Series
HCS01
Mains Voltage
3 x AC 200...500 V ±10%
Other Design Features
None
Pairing Note
Paired with Control Section Design 'BASIC' (B)
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
Safety Interface
Not equipped
  • HCS011EW0028A03AETECDANNNNFW
  • HCS01 1E W0028 A 03 A ET EC DA NN NN FW
  • hcs01.1e-w0018-a-03-b-et-ec-ep-s4-nn-aw
  • HCS1.1E-W0028-A-03-A-ET-EC-DA-NN-NN-FW

Frequently Asked Questions about HCS01.1E-W0028-A-03-A-ET-EC-DA-NN-NN-FW:

Q: What type of communication interface does the HCS01.1E-W0028-A-03-A-ET-EC-DA-NN-NN-FW drive controller support?

A: The HCS01.1E-W0028-A-03-A-ET-EC-DA-NN-NN-FW controller offers MultiEthernet connectivity, allowing for versatile communication options.

Q: How is the HCS01.1E-W0028-A-03-A-ET-EC-DA-NN-NN-FW drive controller cooled?

A: This drive controller features an internal air cooling system that operates through an integrated blower.

Q: What is the device peak current for the HCS01.1E-W0028-A-03-A-ET-EC-DA-NN-NN-FW controller?

A: The peak current supported by this device is 28 A.

Q: What IP rating does the HCS01.1E-W0028-A-03-A-ET-EC-DA-NN-NN-FW drive controller have?

A: The HCS01.1E-W0028-A-03-A-ET-EC-DA-NN-NN-FW provides an IP20 protection rating, which offers basic protection against solid objects.

Q: What mains voltage is supported by the HCS01.1E-W0028-A-03-A-ET-EC-DA-NN-NN-FW controller?

A: This model operates with a mains voltage range of 3 x AC 200 to 500 V ±10%.


Internal Product Review

  • ‘‘The HCS01.1E-W0028-A-03-A-ET-EC-DA-NN-NN-FW is a Bosch Rexroth Indramat HCS drive controller with MultiEthernet communication and internal air cooling through an integrated blower. Support for 3 x AC 200 to 500 V mains voltage and 28 A peak current makes this controller a strong choice for demanding drive applications.’’