4.95 based on 202 reviews

🙶 First-time customer with Wake Industrial. The ordering process was completely seamless. The part that we o... 🙷

HCS01.1E-W0028-A-03-A-CC-EC-PB-S5-NN-FW Bosch Rexroth Indramat

MPN: R911386719

No Tariffs On US Orders
  • Rated 4.5 (31 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
Ask for Availability

Preparing your secure checkout page...

The Bosch Rexroth Indramat HCS01.1E-W0028-A-03-A-CC-EC-PB-S5-NN-FW is part of the HCS IndraDrive Controllers series and serves as an HCS drive controller. It supports a SERCOS III master for cross communication, an encoder IndraDyn Hiperface/EnDat 2.1/2.2 interface, and PROFIBUS connectivity. The unit features an internal air cooling method with a peak device current of 28 Amps and an IP20 rating.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The HCS01.1E-W0028-A-03-A-CC-EC-PB-S5-NN-FW drive controller is produced by Bosch Rexroth Indramat as part of the HCS IndraDrive Controllers series. Positioned in the compact HCS01 line, this unit supplies closed-loop regulation for single-axis or coordinated motion in packaging machines, handling gantries, and general factory automation. It converts mains power, supervises motor feedback, and exchanges status data so that connected axes follow velocity or torque commands with repeatable accuracy.

Its power section accepts a three-phase supply of 3 x AC 200...500 V ±10%, allowing the same unit to be connected to low or medium industrial grids. From that input, the controller can deliver up to 28 A of peak output current, which supports short acceleration bursts without requiring a larger cabinet installation. Thermal energy is removed by internal air cooling with an integrated blower, eliminating the need for external ducting while helping maintain stable operating temperatures. The housing carries a protection rating of IP20, so it is intended for installation inside an enclosed switchgear rack. Drive-to-drive coordination and diagnostic traffic are handled through a SERCOS III master for cross communication channel that reduces fieldbus wiring and supports deterministic cycle times.

The controller is paired with the ADVANCED control section, giving it expanded processing resources for multi-axis interpolation and onboard technology functions. Motor position feedback plugs into the IndraDyn Hiperface or EnDat 2.1/2.2 encoder interface, while higher-level PLC commands can arrive over PROFIBUS when an Ethernet-based motion bus is not selected. The integrated power supply operates in an infeeding and fed configuration, meaning regenerated energy can be shared among multiple axes through a shared DC link.

Communication Interface
SERCOS III master (cross communication)
Control Section Design Type
ADVANCED
Cooling Method
Air, internal (through integrated blower)
Design Version
1
Device Peak Current
28 A
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Interface 2 Type
PROFIBUS
IP Rating
IP20
Line Series
HCS01
Mains Voltage
3 x AC 200...500 V ±10%
Other Design Features
None
Pairing Note
Paired with Control Section Design 'ADVANCED' (A)
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
  • HCS011EW0028A03ACCECPBS5NNFW
  • HCS01 1E W0028 A 03 A CC EC PB S5 NN FW
  • hcs01.1e-w0018-a-03-b-et-ec-ep-l4-nn-fw
  • HCS1.1E-W0028-A-03-A-CC-EC-PB-S5-NN-FW

Frequently Asked Questions about HCS01.1E-W0028-A-03-A-CC-EC-PB-S5-NN-FW:

Q: What communication interface does the HCS01.1E-W0028-A-03-A-CC-EC-PB-S5-NN-FW drive controller use?

A: The HCS01.1E-W0028-A-03-A-CC-EC-PB-S5-NN-FW supports SERCOS III master cross communication as its communication interface.

Q: Which encoder interfaces are compatible with the HCS01.1E-W0028-A-03-A-CC-EC-PB-S5-NN-FW?

A: This drive controller supports connection to encoder systems via the IndraDyn Hiperface and EnDat 2.1/2.2 interfaces.

Q: What is the device peak current for the HCS01.1E-W0028-A-03-A-CC-EC-PB-S5-NN-FW?

A: The peak current for this model is 28 A, allowing it to handle higher momentary loads during operation.

Q: How is the HCS01.1E-W0028-A-03-A-CC-EC-PB-S5-NN-FW cooled?

A: Cooling is achieved via an internal air blower, ensuring consistent airflow within the device.

Q: What mains voltage range does the HCS01.1E-W0028-A-03-A-CC-EC-PB-S5-NN-FW support?

A: The rated mains voltage is 3-phase AC from 200 to 500 V with a ±10% tolerance range.


Internal Product Review

  • ‘‘The HCS01.1E-W0028-A-03-A-CC-EC-PB-S5-NN-FW is an HCS drive controller with an ADVANCED control section design. Internal air cooling through an integrated blower and IP20 protection support clean integration in enclosed automation cabinets. SERCOS III master cross communication and 28 A peak current make the controller an excellent fit for high-response motion applications.’’