HCS01.1E-W0028-A-03-A-CC-EC-NN-NN-NN-FW Bosch Rexroth Indramat
MPN: R911334778
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The Bosch Rexroth Indramat HCS01.1E-W0028-A-03-A-CC-EC-NN-NN-NN-FW is an HCS IndraDrive Controller featuring a SERCOS III master communication interface for cross communication. This drive controller has a peak current of 28 Amps, uses internal air cooling with an integrated blower, and is rated at IP20. It operates with mains voltages from 200 to 500 Volts AC and includes an IndraDyn Hiperface or EnDat 2.1/2.2 encoder interface.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
Bosch Rexroth Indramat produced the HCS01.1E-W0028-A-03-A-CC-EC-NN-NN-NN-FW for use in the HCS IndraDrive Controllers series. This drive controller accepts command data from higher-level control systems and modulates motor current to support coordinated axis motion in industrial automation. The base hardware is fitted with the ADVANCED control section, which adds processing capability for drive-resident motion functions and fieldbus diagnostics. It is intended for applications where the controller must convert network commands into regulated motor output for precise axis response.
The controller exchanges real-time data with upstream PLCs over a SERCOS III master with cross communication channel. Cooling is provided by internal air cooling through an integrated blower, which keeps internal components within temperature limits without external ducting. With a supply window of 3 x AC 200...500 V ±10%, the unit can operate in both 230 V and 480 V plants. The power stage can deliver 28 A peak phase current during brief overloads, which supports rapid acceleration on demanding motion profiles. Its IP20 enclosure requires installation inside a control cabinet. This version uses design version 1, and the second interface slot as well as the safety interface are not populated.
Position feedback is handled through an IndraDyn Hiperface/EnDat 2.1/2.2 encoder interface, which allows the drive to read encoder data directly from compatible motors. Automatic encoder identification helps the drive apply the correct feedback data from the connected motor during setup. The DC link uses an infeeding topology, so regenerated power from one axis can be shared with another axis on the same system. Mechanical dimensions, terminal coding, and parameter ranges follow the HCS01 platform. This configuration is intended for systems that do not require an additional interface channel or an integrated safety option.
Frequently Asked Questions about HCS01.1E-W0028-A-03-A-CC-EC-NN-NN-NN-FW:
Q: What communication interface is available on the HCS01.1E-W0028-A-03-A-CC-EC-NN-NN-NN-FW controller?
A: This model supports a SERCOS III master interface for cross communication.
Q: What is the device peak current rating for the HCS01.1E-W0028-A-03-A-CC-EC-NN-NN-NN-FW?
A: The drive controller can deliver a device peak current of 28 A during operation.
Q: What cooling method is used in the HCS01.1E-W0028-A-03-A-CC-EC-NN-NN-NN-FW?
A: Internal air cooling is provided through an integrated blower on this controller.
Q: What is the supported mains voltage range for the HCS01.1E-W0028-A-03-A-CC-EC-NN-NN-NN-FW?
A: This drive controller features a mains voltage range of 3 x AC 200 to 500 V (±10%).
Q: Which control section design type is incorporated in this model?
A: The HCS01.1E-W0028-A-03-A-CC-EC-NN-NN-NN-FW is built with an ADVANCED control section design type.