HCS01.1E-W0018-A-03-B-ET-EC-PB-NN-AA-FW Bosch Rexroth Indramat

MPN: R911331051

No Tariffs On US Orders
  • Rated 4.5 (31 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
Ask for Availability

Preparing your secure checkout page...

The Bosch Rexroth Indramat HCS01.1E-W0018-A-03-B-ET-EC-PB-NN-AA-FW is part of the HCS IndraDrive Controllers series and is designed as a BASIC control section. This drive controller features MultiEthernet and PROFIBUS interfaces, has a peak current of 18 Amps, and uses internal air cooling through an integrated blower. It has an IP20 rating and operates on a mains voltage of 3 x AC 200 to 500 Volts.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The HCS01.1E-W0018-A-03-B-ET-EC-PB-NN-AA-FW is a drive controller produced by Bosch Rexroth Indramat for the HCS IndraDrive Controllers series. It bridges the incoming mains supply and the motor field wiring, executing closed-loop speed and torque commands in automated packaging, material-handling, and assembly lines. By integrating power electronics, feedback processing, and fieldbus routing inside a narrow housing, the unit serves as the core motion element for single-axis stations that require coordinated and repeatable positioning.

The power section accepts 3 × AC 200…500 V ±10%, allowing operation on 230 V or 400 V networks without hardware changes. This wide input range supports installations with varying supply conditions. During acceleration, it can deliver 18 A of peak output current, which is the short-term motor current limit. Thermal management uses internal air cooling through an integrated blower, so cabinet airflow does not need to pass through the heat sink. Fan speed is controlled by temperature sensors to reduce noise during lighter operating periods. The housing is rated IP20, so live parts must remain inside an enclosed panel. Motion tasks are processed by the BASIC control section, which supports standard positioning loops.

The controller provides a MultiEthernet port that can be switched between PROFINET, EtherNet/IP, and EtherCAT for communication with the plant PLC. For motor feedback, it supports IndraDyn Hiperface or EnDat 2.1 / 2.2 encoder feedback, and a separate channel provides PROFIBUS communication for legacy devices. The unit uses an infeeding and fed supply concept, allowing shared DC-bus energy and regenerative operation. No safety interface is installed. The third design version is indicated by code 03, and the HCS01 product line places the controller within the compact single-axis IndraDrive platform.

Communication Interface
MultiEthernet
Control Section Design Type
BASIC
Cooling Method
Air, internal (through integrated blower)
Design Version
1
Device Peak Current
18 A
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Interface 2 Type
PROFIBUS
IP Rating
IP20
Line Series
HCS01
Mains Voltage
3 x AC 200...500 V ±10%
Pairing Note
Paired with Control Section Design 'BASIC' (B)
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
Safety Interface
Not equipped
  • HCS011EW0018A03BETECPBNNAAFW
  • HCS01 1E W0018 A 03 B ET EC PB NN AA FW
  • hcs01.1e-w0018-a-03-a-cc-ec-pb-s4-nn-fw
  • HCS1.1E-W0018-A-03-B-ET-EC-PB-NN-AA-FW

Frequently Asked Questions about HCS01.1E-W0018-A-03-B-ET-EC-PB-NN-AA-FW:

Q: What type of communication interface does the HCS01.1E-W0018-A-03-B-ET-EC-PB-NN-AA-FW support?

A: The HCS01.1E-W0018-A-03-B-ET-EC-PB-NN-AA-FW offers MultiEthernet as its communication interface for versatile network connectivity.

Q: What is the maximum peak current for the HCS01.1E-W0018-A-03-B-ET-EC-PB-NN-AA-FW?

A: This drive controller supports a device peak current of 18 A for demanding applications.

Q: How is the HCS01.1E-W0018-A-03-B-ET-EC-PB-NN-AA-FW cooled?

A: Air cooling is achieved through an integrated blower inside the unit.

Q: What is the supported mains voltage for the HCS01.1E-W0018-A-03-B-ET-EC-PB-NN-AA-FW drive controller?

A: The mains voltage range for this controller is three-phase AC 200 to 500 V ±10%.

Q: What is the IP rating of the HCS01.1E-W0018-A-03-B-ET-EC-PB-NN-AA-FW?

A: The enclosure of this device has an IP20 rating, providing basic protection against solid objects.


Internal Product Review

  • ‘‘The HCS01.1E-W0018-A-03-B-ET-EC-PB-NN-AA-FW is an HCS drive controller with BASIC control architecture and MultiEthernet communication. Internal blower cooling supports stable thermal performance, and 18 A peak current gives the unit strong drive capability for demanding motion axes. Support for 3 x AC 200 to 500 V mains and PROFIBUS integration makes the controller a highly practical choice for flexible industrial drive systems.’’