HCS01.1E-W0018-A-03-B-ET-EC-PB-L4-NN-AW Bosch Rexroth Indramat
MPN: R911399973
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The Bosch Rexroth Indramat HCS01.1E-W0018-A-03-B-ET-EC-PB-L4-NN-AW is a drive controller from the HCS IndraDrive Controllers series. It features a MultiEthernet communication interface, PROFIBUS, and supports IndraDyn Hiperface or EnDat 2.1/2.2 encoders. The unit offers up to 18 amps peak current, air cooling through an internal blower, and comes with STO and SBC safety interfaces.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The HCS01.1E-W0018-A-03-B-ET-EC-PB-L4-NN-AW is a drive controller produced by Bosch Rexroth Indramat within the HCS IndraDrive Controllers series. In multi-axis industrial automation, this unit modulates AC power for synchronous and induction motors while synchronizing motion with machine commands issued by higher-level PLCs. By combining power electronics, control logic, and fieldbus connectivity in one housing, the controller serves as the core of compact drive cabinets for packaging, material handling, and general motion platforms.
It operates from a three-phase supply of 3 × AC 200…500 V ±10 %, allowing the same hardware to be used on low- or mid-voltage plant grids without tap changes. During acceleration or regeneration, the power stage can source up to 18 A of peak current, which suits low- to medium-inertia axes in the HCS01 line. Heat is expelled by an internal air blower, so no external heat sink is required. A MultiEthernet port provides standard TCP/IP, EtherNet/IP, PROFINET, and EtherCAT services for parameter access and real-time cyclic data, while the enclosure’s IP20 rating limits installation to clean, protected electrical enclosures. The power supply section supports infeeding and fed operation, permitting energy exchange between interconnected drives on a common DC bus.
The controller uses a control section classified as BASIC with Design Version 1, which provides the I/O logic for this configuration. For motion feedback, Interface 1 accepts Encoder IndraDyn Hiperface/EnDat 2.1/2.2 signals, enabling absolute position evaluation over a single cable. Networked device coordination can also rely on the dedicated PROFIBUS port when a legacy fieldbus is required. Safety circuits are embedded directly in the power stage through STO and SBC functions, providing certified torque and brake shutdown when an emergency stop, guard door, or light curtain is triggered.
Frequently Asked Questions about HCS01.1E-W0018-A-03-B-ET-EC-PB-L4-NN-AW:
Q: What type of communication interface does the HCS01.1E-W0018-A-03-B-ET-EC-PB-L4-NN-AW offer?
A: This model supports MultiEthernet for versatile network integration.
Q: What is the peak current rating for this IndraDrive controller?
A: The HCS01.1E-W0018-A-03-B-ET-EC-PB-L4-NN-AW achieves a device peak current of 18 A.
Q: How is the HCS01.1E-W0018-A-03-B-ET-EC-PB-L4-NN-AW cooled?
A: It uses an internal air cooling method with an integrated blower for thermal management.
Q: Does the HCS01.1E-W0018-A-03-B-ET-EC-PB-L4-NN-AW have safety features like STO and SBC?
A: Yes, this unit has safety interfaces for Safe Torque Off (STO) and Safe Brake Control (SBC).
Q: What mains voltage range does this drive controller support?
A: The HCS01.1E-W0018-A-03-B-ET-EC-PB-L4-NN-AW supports a mains voltage supply of 3 x AC 200 to 500 V with a ±10% tolerance.