4.95 based on 202 reviews

🙶 We have never had a problem in the almost 20 years we have dealt with Wake. We would recommend them to any... 🙷

HCS01.1E-W0018-A-03-B-ET-EC-NN-S4-NN-PW Bosch Rexroth Indramat

MPN: R911372695

No Tariffs On US Orders
  • Rated 4.4 (29 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
Ask for Availability

Preparing your secure checkout page...

The Bosch Rexroth Indramat HCS01.1E-W0018-A-03-B-ET-EC-NN-S4-NN-PW is part of the HCS IndraDrive Controllers series and has a peak device current of 18 Amps. This drive controller features an internal air cooling method with an integrated blower, and supports MultiEthernet communication as well as encoder interfaces including IndraDyn Hiperface and EnDat 2.1/2.2. It has an IP20 rating and operates with a mains voltage range of 200 to 500 Volts AC.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The HCS01.1E-W0018-A-03-B-ET-EC-NN-S4-NN-PW drive controller is manufactured by Bosch Rexroth Indramat as part of the HCS IndraDrive Controllers series. Within an automation cell, this controller converts incoming three-phase power into regulated motor current while exchanging command and status data with higher-level control hardware. It is intended for cabinet installation where it supervises axis current, monitors feedback, and coordinates torque and speed profiles in real time.

Incoming supply flexibility is provided by a mains range of 3 x AC 200–500 V ±10%, allowing the same hardware to be wired to different plant distributions. Heat produced by the power electronics is removed through internal air cooling that relies on an integrated blower, so no additional cabinet fan module is required. The controller can deliver a device peak current of 18 A to handle acceleration peaks without saturation. Its enclosure carries an IP20 rating, so the unit must be mounted inside a protected panel while the terminals remain finger-safe. Fieldbus and diagnostic traffic are handled by a MultiEthernet port that supports several real-time Ethernet protocols through the same connector.

The drive uses the BASIC control section and provides standard motion functions without extra technology options. Feedback wiring is routed to a combined encoder socket that accepts Encoder IndraDyn Hiperface/EnDat 2.1/2.2 feedback signals, ensuring compatibility with current Rexroth servo motors. A second encoder interface is not included. The device belongs to the HCS01 line and design version 1, so its mechanical dimensions align with other controllers in the same frame size. Energy is exchanged on a common DC bus with an Infeeding / Feeded configuration, enabling the unit to either supply or absorb power and support regenerative braking.

Communication Interface
MultiEthernet
Control Section Design Type
BASIC
Cooling Method
Air, internal (through integrated blower)
Design Version
1
Device Peak Current
18 A
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Interface 2 Type
Not equipped
IP Rating
IP20
Line Series
HCS01
Mains Voltage
3 x AC 200...500 V ±10%
Other Design Features
None
Pairing Note
Paired with Control Section Design 'BASIC' (B)
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
  • HCS011EW0018A03BETECNNS4NNPW
  • HCS01 1E W0018 A 03 B ET EC NN S4 NN PW
  • hcs01.1e-w0018-a-03-a-cc-ec-nn-nn-nn-fw
  • HCS1.1E-W0018-A-03-B-ET-EC-NN-S4-NN-PW

Frequently Asked Questions about HCS01.1E-W0018-A-03-B-ET-EC-NN-S4-NN-PW:

Q: What communication interface is available on the HCS01.1E-W0018-A-03-B-ET-EC-NN-S4-NN-PW drive controller?

A: The HCS01.1E-W0018-A-03-B-ET-EC-NN-S4-NN-PW supports MultiEthernet as its communication interface, allowing for flexible industrial networking.

Q: What is the mains voltage range for the HCS01.1E-W0018-A-03-B-ET-EC-NN-S4-NN-PW drive controller?

A: This controller operates with a three-phase AC mains voltage from 200 to 500 V, with a tolerance of plus or minus 10%.

Q: How is the HCS01.1E-W0018-A-03-B-ET-EC-NN-S4-NN-PW drive controller cooled?

A: The HCS01.1E-W0018-A-03-B-ET-EC-NN-S4-NN-PW features internal air cooling through an integrated blower.

Q: What is the peak current rating of the HCS01.1E-W0018-A-03-B-ET-EC-NN-S4-NN-PW drive controller?

A: This model offers a peak device current of 18 A for demanding applications.

Q: What level of ingress protection does the HCS01.1E-W0018-A-03-B-ET-EC-NN-S4-NN-PW provide?

A: The HCS01.1E-W0018-A-03-B-ET-EC-NN-S4-NN-PW has an IP20 rating, providing basic protection against solid objects.


Internal Product Review

  • ‘‘The HCS01.1E-W0018-A-03-B-ET-EC-NN-S4-NN-PW is an HCS drive controller with MultiEthernet communication and a BASIC control section. Internal blower cooling and a 3 x AC 200 to 500 V input make this unit a strong fit for stable cabinet integration and dependable drive performance.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo