HCS01.1E-W0018-A-03-B-ET-EC-NN-S4-NN-AW Bosch Rexroth Indramat
MPN: R911392471
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The Bosch Rexroth Indramat HCS01.1E-W0018-A-03-B-ET-EC-NN-S4-NN-AW is part of the HCS IndraDrive Controllers series and is designed as an HCS drive controller. It features a MultiEthernet communication interface, has an internal air cooling method with integrated blower, and offers a device peak current of 18 Amps. The controller has an IP20 protection rating and supports encoder interfaces including IndraDyn Hiperface and EnDat 2.1/2.2.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The HCS01.1E-W0018-A-03-B-ET-EC-NN-S4-NN-AW is a drive controller produced by Bosch Rexroth Indramat and delivered as part of the HCS IndraDrive Controllers series. This model integrates power conversion, motion control, and fieldbus connectivity so that a single frame can command rotary or linear servo axes on automated assembly lines, packaging machines, or handling stations. It is suited for servo applications that require coordinated motor control and networked communication in one compact unit. Because it follows the HCS01 format, it shares mounting dimensions and wiring schemes with neighboring units in the line, which helps simplify cabinet layout in multi-axis installations.
The power section accepts a three-phase supply of 3 x AC 200–500 V ±10% and can deliver a device peak current of 18 A during brief acceleration or braking events. This short-term current capability supports temporary load changes during speed ramps and indexing moves. Thermal energy is removed by internal air cooling through an integrated blower, so no external heat sink is required. The controller has an IP20 enclosure rating, which protects against accidental contact with internal parts but does not protect against liquids. System communication is handled through MultiEthernet, giving the controller direct access to standard industrial Ethernet protocols without additional option cards. This allows the drive to exchange control data with the higher-level system over a common network connection.
The control section uses the BASIC design, which indicates the standard control configuration for this model. Position feedback enters through the IndraDyn Hiperface/EnDat 2.1/2.2 encoder interface, allowing compatibility with supported motor feedback systems. This feedback path supports closed-loop position and speed control when the drive is paired with a compatible motor. A second feedback slot is not equipped. Energy is exchanged with the DC bus through an infeeding and fed power supply arrangement, and the unit is built as Design Version 1.
Frequently Asked Questions about HCS01.1E-W0018-A-03-B-ET-EC-NN-S4-NN-AW:
Q: What type of communication interface is provided on the HCS01.1E-W0018-A-03-B-ET-EC-NN-S4-NN-AW model?
A: This drive controller features a MultiEthernet communication interface for network connectivity.
Q: What is the maximum device peak current supported by the HCS01.1E-W0018-A-03-B-ET-EC-NN-S4-NN-AW?
A: The HCS01.1E-W0018-A-03-B-ET-EC-NN-S4-NN-AW has a peak current rating of 18 A.
Q: How is the HCS01.1E-W0018-A-03-B-ET-EC-NN-S4-NN-AW cooled during operation?
A: This drive controller uses an internal air-cooling method by means of an integrated blower.
Q: What encoder feedback interface is available on the HCS01.1E-W0018-A-03-B-ET-EC-NN-S4-NN-AW?
A: The encoder interface supports IndraDyn, Hiperface, and EnDat 2.1/2.2 feedback protocols.
Q: What mains voltage range is required to power the HCS01.1E-W0018-A-03-B-ET-EC-NN-S4-NN-AW drive controller?
A: This unit operates with a 3-phase AC supply voltage of 200 to 500 V, ±10%.