HCS01.1E-W0018_A-03-B-ET-EC-NN-NN-NN-FW Bosch Rexroth Indramat

MPN: R911325247

No Tariffs On US Orders
  • Rated 4.6 (57 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
In-Stock, Ships 3-5 Days

Preparing your secure checkout page...

The Bosch Rexroth Indramat HCS01.1E-W0018_A-03-B-ET-EC-NN-NN-NN-FW is a drive controller from the HCS IndraDrive Controllers series. It features a device peak current of 18 Amps and supports MultiEthernet communication. This model has an IP20 rating, uses internal air cooling with an integrated blower, and operates on a mains voltage range of 3 x AC 200 to 500 Volts with plus or minus 10 percent tolerance.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The HCS01.1E-W0018_A-03-B-ET-EC-NN-NN-NN-FW is a drive controller produced by Bosch Rexroth Indramat for the HCS IndraDrive Controllers series. It serves as the central power and regulation stage between the plant mains and connected servo or induction motors in industrial automation systems. By modulating three-phase supply energy and exchanging real-time status data with higher-level motion controls, the unit manages speed, torque, and positioning functions across multi-axis machinery. In operation, it converts incoming electrical power into controlled motor output for precise axis response during synchronized machine movement.

It accepts a three-phase mains supply of 200–500 V AC ±10% and can deliver up to 18 A of peak output current to the motor windings, allowing brief acceleration or braking events without immediate derating. Communication for setup and diagnostics is handled through the MultiEthernet interface, making the controller adaptable to EtherNet/IP, PROFINET, or EtherCAT network topologies. Position feedback is connected through the single-cable Encoder IndraDyn Hiperface/EnDat 2.1/2.2 port so the drive can close the velocity and position loops internally. This arrangement supports closed-loop control while keeping the motor feedback connection on one dedicated interface. The cabinet-mounted housing has an IP20 rating, so it must be installed inside an electrical enclosure for additional protection.

The power section is paired with a control board marked BASIC, and this combination corresponds to version 1 within the HCS01 line. Heat from semiconductor switching is removed by an integrated blower, so no external cooling air path is required for nominal duty. The DC supply concept supports infeeding and feeding, which allows the device to draw energy from or return energy to a shared bus. The drive is not equipped with a safety interface, and the optional fieldbus expansion slot is empty. With no plug-in fieldbus card installed, communication remains dependent on the built-in interface provided on the unit.

Communication Interface
MultiEthernet
Control Section Design Type
BASIC
Cooling Method
Air, internal (through integrated blower)
Design Version
1
Device Peak Current
18 A
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Interface 2 Type
Not equipped
IP Rating
IP20
Line Series
HCS01
Mains Voltage
3 x AC 200...500 V ±10%
Other Design Features
None
Pairing Note
Paired with Control Section Design 'BASIC' (B)
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
Safety Interface
Not equipped
  • HCS011EW0018_A03BETECNNNNNNFW
  • HCS01 1E W0018_A 03 B ET EC NN NN NN FW
  • hcs01.1e-w0018-a-03-b-et-ec-cn-l3-nn-fw
  • HCS1.1E-W0018_A-03-B-ET-EC-NN-NN-NN-FW

Frequently Asked Questions about HCS01.1E-W0018_A-03-B-ET-EC-NN-NN-NN-FW:

Q: How is the HCS01.1E-W0018_A-03-B-ET-EC-NN-NN-NN-FW drive controller cooled?

A: The HCS01.1E-W0018_A-03-B-ET-EC-NN-NN-NN-FW features an internal air cooling system using an integrated blower.

Q: What is the peak current rating for the HCS01.1E-W0018_A-03-B-ET-EC-NN-NN-NN-FW?

A: This unit offers a device peak current of 18 A for demanding operational periods.

Q: Which communication interface is supported by this drive controller?

A: The HCS01.1E-W0018_A-03-B-ET-EC-NN-NN-NN-FW supports MultiEthernet communication for flexible connectivity.

Q: What is the IP rating of the HCS01.1E-W0018_A-03-B-ET-EC-NN-NN-NN-FW?

A: This drive controller has an IP20 rating, providing basic protection against solid objects.

Q: What are the mains voltage requirements for this model?

A: The HCS01.1E-W0018_A-03-B-ET-EC-NN-NN-NN-FW is compatible with a mains voltage of 3 x AC 200...500 V ±10%.


Internal Product Review

  • ‘‘The HCS01.1E-W0018_A-03-B-ET-EC-NN-NN-NN-FW is an HCS drive controller that stands out for MultiEthernet communication and a BASIC control section. Internal blower cooling and 18 A peak current support stable cabinet integration and responsive drive performance, making the unit a strong fit for general automation duty.’’