4.95 based on 202 reviews

🙶 I have always received exceptional service and support in my many years of working with Wake Industrial. 🙷

HCS01.1E-W0018-A-03-B-ET-EC-NN-NN-AA-FW Bosch Rexroth Indramat

MPN: R911331050

No Tariffs On US Orders
  • Rated 4.7 (26 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
Ask for Availability

Preparing your secure checkout page...

The Bosch Rexroth Indramat HCS01.1E-W0018-A-03-B-ET-EC-NN-NN-AA-FW is part of the HCS IndraDrive Controllers series and is designed as a HCS drive controller with a BASIC control section. The device supports MultiEthernet communication, operates with a peak current of 18 Amps, and has an IP20 rating. Cooling is provided by internal air through an integrated blower, and it uses an encoder IndraDyn Hiperface or EnDat 2.1/2.2 interface.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The Bosch Rexroth Indramat HCS01.1E-W0018-A-03-B-ET-EC-NN-NN-AA-FW belongs to the HCS01 line in the HCS IndraDrive Controllers series. As an HCS drive controller, it supplies regulated three-phase power and handles position, speed, and torque control for servo or induction motors used in automated handling, packaging, and conveying equipment. The unit combines a power section with a modular control section, allowing it to exchange motion commands and diagnostic data with supervisory PLCs over standard plant networks. This supports coordinated axis behavior during starting, stopping, indexing, and speed changes in compact machine installations.

The drive accepts a wide-range input of 3 x AC 200 to 500 V ±10%, so the same hardware can operate on different utility grids. Network communication is handled through MultiEthernet, which supports PROFINET, EtherNet/IP, and EtherCAT without additional option cards. Its IP20 housing is finger-safe but still requires cabinet installation for protection from dust and moisture. Heat from the power stage is removed by internal air cooling through an integrated blower, and the inverter can deliver a peak phase current of 18 A during short acceleration demands. Because cooling is internal, the cabinet still needs adequate airflow around the drive to carry heat away from the enclosure.

The control section uses the BASIC variant, so the drive follows the standard motion and parameter feature set for this platform. Position feedback is received through an IndraDyn Hiperface/EnDat 2.1/2.2 encoder interface, allowing high-resolution commutation without external converters. The drive supports Infeeding / Feeded operation, which lets multiple units share a common DC bus and return regenerated energy to the line. The unit is Design Version 1, and the secondary communication and safety interface slots are not equipped. This arrangement suits applications that need core motion control without extra interface hardware.

Communication Interface
MultiEthernet
Control Section Design Type
BASIC
Cooling Method
Air, internal (through integrated blower)
Design Version
1
Device Peak Current
18 A
Firmware Order Note
Firmware must be ordered as separate sub position
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Interface 2 Type
Not equipped
IP Rating
IP20
Line Series
HCS01
Mains Voltage
3 x AC 200...500 V ±10%
Pairing Note
Paired with Control Section Design 'BASIC' (B)
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
Safety Interface
Not equipped
  • HCS011EW0018A03BETECNNNNAAFW
  • HCS01 1E W0018 A 03 B ET EC NN NN AA FW
  • hcs01.1e-w0018-a-03-a-cc-ec-et-s4-nn-fw
  • HCS1.1E-W0018-A-03-B-ET-EC-NN-NN-AA-FW

Frequently Asked Questions about HCS01.1E-W0018-A-03-B-ET-EC-NN-NN-AA-FW:

Q: What communication interface does the HCS01.1E-W0018-A-03-B-ET-EC-NN-NN-AA-FW drive controller use?

A: The HCS01.1E-W0018-A-03-B-ET-EC-NN-NN-AA-FW supports MultiEthernet communication interfaces.

Q: What is the peak current rating for the HCS01.1E-W0018-A-03-B-ET-EC-NN-NN-AA-FW?

A: This controller has a device peak current of 18 A for handling demanding drive operations.

Q: How is the HCS01.1E-W0018-A-03-B-ET-EC-NN-NN-AA-FW drive controller cooled?

A: The HCS01.1E-W0018-A-03-B-ET-EC-NN-NN-AA-FW uses an internal air cooling method with an integrated blower.

Q: What IP rating does the HCS01.1E-W0018-A-03-B-ET-EC-NN-NN-AA-FW have?

A: This drive controller has an IP20 rating and is suitable for protected indoor environments.

Q: What is the mains voltage range for the HCS01.1E-W0018-A-03-B-ET-EC-NN-NN-AA-FW controller?

A: The mains voltage for this model ranges from 3 x AC 200 to 500 V with a ±10% tolerance.


Internal Product Review

  • ‘‘The HCS01.1E-W0018-A-03-B-ET-EC-NN-NN-AA-FW is a Bosch Rexroth IndraDrive controller featuring MultiEthernet communication and a device peak current of 18 A, making it suitable for demanding motion applications. Its integrated internal air cooling and IP20 rating support dependable operation in well-ventilated industrial environments. The inclusion of a BASIC control section and advanced encoder compatibility make this drive controller a highly flexible solution.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo