The Bosch Rexroth Indramat HCS01.1E-W0018-A-03-B-ET-EC-NN-L4-AA-FW is a drive controller from the HCS IndraDrive Controllers series. It provides a device peak current of 18 Amps and operates on a mains voltage of 3 x AC 200 to 500 V. This controller features a MultiEthernet communication interface and includes STO and SBC safety interfaces.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The HCS01.1E-W0018-A-03-B-ET-EC-NN-L4-AA-FW is an HCS drive controller built by Bosch Rexroth Indramat within the HCS IndraDrive Controllers series. The unit serves as the central power and control interface between the plant supply network and a servo motor, converting incoming AC power for controlled axis operation. It supports precise positioning, speed regulation, and coordinated motion in automated production equipment. Its single-axis format makes it suitable for machine layouts where each motor channel is managed by a dedicated controller.

Communication with higher-level PLCs uses the MultiEthernet port, allowing access to several Ethernet-based fieldbus systems without extra hardware. The power section accepts 3 x AC 200–500 V ±10% input and can deliver up to 18 A of peak current for short acceleration demands on low- to mid-power servo axes. Heat is removed by internal air cooling, with an integrated blower that keeps air moving through the unit without external ducting. Protection is limited to IP20, so the drive must be installed inside a closed control cabinet. This controller belongs to the HCS01 line and is design version 1, which places it within the compact IndraDrive platform for cabinet-mounted motion control.

The control section uses the BASIC variant, and interface slot 1 is prepared for Encoder IndraDyn Hiperface/EnDat 2.1/2.2 feedback, which supports common motor feedback connections used with Rexroth and compatible motors. Slot 2 is unequipped, so the drive remains focused on applications that do not need a second interface module. Power is handled through an infeeding and fed supply arrangement, allowing the unit to share a common DC bus with other axes and use regenerated energy available on that bus. Functional safety is provided by STO (Safe Torque Off) and SBC (Safe Brake Control) channels that act directly on the output stage and motor brake control path. This layout supports closed-loop motion tasks while keeping the electrical structure straightforward for cabinet integration.

Communication Interface
MultiEthernet
Control Section Design Type
BASIC
Cooling Method
Air, internal (through integrated blower)
Design Version
1
Device Peak Current
18 A
Firmware Order Note
Firmware must be ordered as separate sub position
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Interface 2 Type
Not equipped
IP Rating
IP20
Line Series
HCS01
Mains Voltage
3 x AC 200...500 V ±10%
Pairing Note
Paired with Control Section Design 'BASIC' (B)
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
Safety Interface
STO (Safe Torque Off) and SBC (Safe Brake Control)
  • HCS011EW0018A03BETECNNL4AAFW
  • HCS01 1E W0018 A 03 B ET EC NN L4 AA FW
  • hcs01.1e-w0018-a-03-a-cc-ec-et-l4-nn-fw
  • HCS1.1E-W0018-A-03-B-ET-EC-NN-L4-AA-FW

Frequently Asked Questions about HCS01.1E-W0018-A-03-B-ET-EC-NN-L4-AA-FW:

Q: What communication interface is available on the HCS01.1E-W0018-A-03-B-ET-EC-NN-L4-AA-FW drive controller?

A: The HCS01.1E-W0018-A-03-B-ET-EC-NN-L4-AA-FW offers MultiEthernet communication compatibility for versatile industrial network integration.

Q: What cooling method is used by the HCS01.1E-W0018-A-03-B-ET-EC-NN-L4-AA-FW?

A: This drive controller uses an internal air cooling system with an integrated blower for temperature regulation.

Q: What is the peak current capability of the HCS01.1E-W0018-A-03-B-ET-EC-NN-L4-AA-FW?

A: The device supports a peak current of 18 A, allowing for high power output during demanding operations.

Q: What type of encoder interface is present on the HCS01.1E-W0018-A-03-B-ET-EC-NN-L4-AA-FW?

A: This controller is equipped with an encoder interface supporting IndraDyn Hiperface and EnDat 2.1/2.2 feedback protocols.

Q: What safety interfaces are included on the HCS01.1E-W0018-A-03-B-ET-EC-NN-L4-AA-FW?

A: The HCS01.1E-W0018-A-03-B-ET-EC-NN-L4-AA-FW features the STO (Safe Torque Off) and SBC (Safe Brake Control) safety interfaces.


Internal Product Review

  • ‘‘The HCS01.1E-W0018-A-03-B-ET-EC-NN-L4-AA-FW is a Bosch Rexroth IndraDrive controller equipped with a MultiEthernet interface and a peak current capacity of 18 A. Internal air cooling via an integrated blower delivers efficient thermal management, while IP20 protection supports safe installation in cabinet environments. Safety features include STO (Safe Torque Off) and SBC (Safe Brake Control), making this drive controller a dependable option for advanced automation.’’