HCS01.1E-W0018-A-03-B-ET-EC-EP-SB-NN-AW Bosch Rexroth Indramat
MPN: R911397095
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The Bosch Rexroth Indramat HCS01.1E-W0018-A-03-B-ET-EC-EP-SB-NN-AW is part of the HCS IndraDrive Controllers series and is designed as a BASIC control section drive controller. It features a MultiEthernet communication interface and supports encoder interfaces such as IndraDyn Hiperface and EnDat 2.1/2.2. The device offers a peak current of 18 Amps, uses internal air cooling through an integrated blower, and has an IP20 rating.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The HCS01.1E-W0018-A-03-B-ET-EC-EP-SB-NN-AW is a drive controller from Bosch Rexroth Indramat in the HCS IndraDrive Controllers series. It links a three-phase mains supply to servo or induction axes so that speed, torque, and position follow PLC commands in automated machinery. In practical use, it serves as the power and control stage between the incoming supply and the motor, supporting coordinated axis movement in packaging, handling, and general factory systems. The unit is an HCS drive controller with design version 1 and no additional design features, giving it a streamlined configuration for standard motion tasks.
The controller communicates with higher-level systems over MultiEthernet, allowing TCP/IP-based fieldbus selection without hardware changes. It accepts a supply of 3 x AC 200 to 500 V ±10%, which supports installation on a wide range of industrial power systems. Inside the power stage, a peak output of 18 A is available for short acceleration periods before current limiting begins. Motor feedback is handled through an IndraDyn Hiperface/EnDat 2.1/2.2 encoder interface, so the drive can process both absolute and incremental position signals. The enclosure has an IP20 rating, which provides basic finger protection and requires installation in a closed cabinet where dust or fluids may be present.
Thermal management relies on internal air cooling through an integrated blower, so the unit uses cabinet air and does not require external ducting. The integrated blower moves air through the heat-sink channels, helping remove thermal load during continuous operation. The control section is the BASIC type, which limits the drive to standard motion functions rather than advanced technology packages. The unit belongs to the HCS01 line and is configured for infeeding and fed operation, allowing it to share a common DC bus with matching converters.
Frequently Asked Questions about HCS01.1E-W0018-A-03-B-ET-EC-EP-SB-NN-AW:
Q: What communication interface does the HCS01.1E-W0018-A-03-B-ET-EC-EP-SB-NN-AW controller use?
A: The HCS01.1E-W0018-A-03-B-ET-EC-EP-SB-NN-AW supports MultiEthernet communication for versatile network connectivity.
Q: What is the cooling method used in the HCS01.1E-W0018-A-03-B-ET-EC-EP-SB-NN-AW?
A: This drive controller features an integrated blower for internal air cooling.
Q: What is the device peak current for the HCS01.1E-W0018-A-03-B-ET-EC-EP-SB-NN-AW?
A: The device has a peak current capacity of 18 A for demanding applications.
Q: What is the IP rating of the HCS01.1E-W0018-A-03-B-ET-EC-EP-SB-NN-AW?
A: This model is rated IP20, offering basic protection against solid objects but not water.
Q: What is the mains voltage requirement for the HCS01.1E-W0018-A-03-B-ET-EC-EP-SB-NN-AW?
A: It operates on a three-phase AC mains voltage range of 200 to 500 V with a ±10% tolerance.