4.95 based on 202 reviews

🙶 I have always received exceptional service and support in my many years of working with Wake Industrial. 🙷

HCS01.1E-W0018-A-03-B-ET-EC-EP-S4-NN-AW Bosch Rexroth Indramat

MPN: R911394991

No Tariffs On US Orders
  • Rated 4.4 (49 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
Ask for Availability

Preparing your secure checkout page...

The Bosch Rexroth Indramat HCS01.1E-W0018-A-03-B-ET-EC-EP-S4-NN-AW is an HCS Drive Controller in the HCS IndraDrive Controllers series. It features a MultiEthernet communication interface, encoder compatibility with IndraDyn Hiperface and EnDat 2.1/2.2, and an IP20 rating. The device operates with a peak current of 18 Amps and supports a mains voltage range of 3 x AC 200 to 500 V plus or minus 10 percent.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The HCS01.1E-W0018-A-03-B-ET-EC-EP-S4-NN-AW drive controller is produced by Bosch Rexroth Indramat for the HCS IndraDrive Controllers series. It functions as a compact servo inverter that converts supply power into controlled three-phase output for coordinated motor motion in packaging lines, handling gantries, and general factory automation. It is intended for applications where precise speed and position control must be maintained during repeated machine cycles. When paired with a suitable control section, the drive supplies the command, monitoring, and protective logic needed to synchronize axes. This arrangement helps reduce cabinet space and wiring demands in compact multi-axis installations.

The power section accepts a nominal supply of 3 x AC 200...500 V ±10%, so the same drive platform can operate on North American or international power systems without tap changes. Within this window, the drive can supply a device peak current of 18 A, covering fast acceleration or regenerative braking events before thermal foldback becomes active. Heat generated by the IGBTs is removed by internal air cooling through an integrated blower, eliminating external ducting and keeping cabinet airflow predictable. The enclosure is rated IP20, meaning the controller must be mounted inside an enclosed panel. Command and diagnostic data are exchanged through MultiEthernet, which supports standardized industrial Ethernet protocols from a single port.

The electrical portion uses the BASIC control section, which provides parameter storage, local I/O, and real-time control algorithms at the drive level. Its functions support local processing of status and motion-related data without requiring an expanded technology package. Position feedback is routed through the front-panel connector that accepts IndraDyn Hiperface and EnDat 2.1/2.2 encoder signals, so absolute and incremental encoders can be used with the drive. This feedback flexibility supports use with several compatible motor and encoder combinations. The power interface supports infeeding or fed operation, allowing the axis to receive DC bus energy from a supply module or return regenerated power to the line. The unit is Design Version 1 within the HCS01 architecture.

Communication Interface
MultiEthernet
Control Section Design Type
BASIC
Cooling Method
Air, internal (through integrated blower)
Design Version
1
Device Peak Current
18 A
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
IP Rating
IP20
Line Series
HCS01
Mains Voltage
3 x AC 200...500 V ±10%
Other Design Features
None
Pairing Note
Paired with Control Section Design 'BASIC' (B)
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
  • HCS011EW0018A03BETECEPS4NNAW
  • HCS01 1E W0018 A 03 B ET EC EP S4 NN AW
  • hcs01.1e-w0018-a-03-a-cc-ec-ec-l4-nn-fw
  • HCS1.1E-W0018-A-03-B-ET-EC-EP-S4-NN-AW

Frequently Asked Questions about HCS01.1E-W0018-A-03-B-ET-EC-EP-S4-NN-AW:

Q: What is the peak current supported by the HCS01.1E-W0018-A-03-B-ET-EC-EP-S4-NN-AW controller?

A: The HCS01.1E-W0018-A-03-B-ET-EC-EP-S4-NN-AW drive controller has a device peak current rating of 18 A.

Q: How is the HCS01.1E-W0018-A-03-B-ET-EC-EP-S4-NN-AW drive controller cooled?

A: This model uses an internal air cooling system with an integrated blower.

Q: What communication interface does the HCS01.1E-W0018-A-03-B-ET-EC-EP-S4-NN-AW support?

A: The communication interface provided on this drive is MultiEthernet, allowing connectivity with various industrial Ethernet networks.

Q: What mains voltage range is required for the HCS01.1E-W0018-A-03-B-ET-EC-EP-S4-NN-AW?

A: This controller supports mains voltages from 3 x AC 200 to 500 V with a ±10% tolerance.

Q: What is the IP rating of the HCS01.1E-W0018-A-03-B-ET-EC-EP-S4-NN-AW controller?

A: The ingress protection rating for this drive controller is IP20, providing basic protection against solid objects.


Internal Product Review

  • ‘‘The HCS01.1E-W0018-A-03-B-ET-EC-EP-S4-NN-AW is an HCS drive controller with MultiEthernet communication and a BASIC control section. Internal air cooling through an integrated blower supports stable thermal performance, and the IP20 rating fits well in protected industrial cabinets. An 18 A peak current with 3 x AC 200...500 V input makes this controller a strong choice for versatile motion applications.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo