HCS01.1E-W0018-A-03-B-ET-EC-EP-L4-NN-FW Bosch Rexroth Indramat
Wake Industrial LLC is not an authorized distributor of this product.
MPN: R911378004
The Bosch Rexroth Indramat HCS01.1E-W0018-A-03-B-ET-EC-EP-L4-NN-FW is part of the HCS IndraDrive Controllers series and uses an air cooling method with an integrated blower. This drive controller features a MultiEthernet communication interface, has a peak device current of 18 Amps, and includes STO and SBC safety interfaces. It operates at a mains voltage of 3 x AC 200 to 500 Volts and offers IP20 protection.
Internal Product Review
The HCS01.1E-W0018-A-03-B-ET-EC-EP-L4-NN-FW is a Bosch Rexroth Indramat HCS drive controller with MultiEthernet communication. Internal blower cooling and 18 A peak current support efficient thermal control and confident drive performance in demanding panels. IP20 protection and STO/SBC safety functions make this controller a strong choice for modern motion applications.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The HCS01.1E-W0018-A-03-B-ET-EC-EP-L4-NN-FW is a drive controller manufactured by Bosch Rexroth Indramat within the HCS IndraDrive Controllers series. It functions as the power and control element that conditions AC mains power, interprets feedback data, and delivers controlled current to servo or induction motors used in automated packaging, material-handling, and assembly cells. This arrangement allows the controller to support coordinated motion tasks where stable speed regulation, torque control, and responsive axis behavior are required during normal machine operation.
Housed in an IP20-rated enclosure, the unit accepts a three-phase mains range of 3 x AC 200...500 V ±10%. Internal thermal management relies on internal air cooling driven by an integrated blower, so no external ducting is required. The communication backbone is MultiEthernet, allowing the same hardware platform to operate with Ethernet-based industrial networks. During acceleration or load shocks, the inverter can supply up to 18 A of peak current while built-in sensors monitor overload limits. Because the enclosure is intended for cabinet installation, shielded RJ45 connections can be used to maintain real-time data exchange with distributed machine components.
The control section is identified as BASIC. Functional safety is provided through STO and Safe Brake Control, allowing immediate torque shutdown and brake actuation without external relays. DC-bus energy is handled by the infeeding and fed supply arrangement, which allows multiple controllers to share regenerative power on a common bus. Position feedback is processed through the IndraDyn Hiperface/EnDat 2.1/2.2 encoder interface, supporting compatible motor feedback devices used with this drive platform. No additional design features are included, so the unit remains in the standard HCS01 configuration for mounting and wiring.