HCS01.1E-W0018-A-03-B-ET-EC-EP-DA-NN-FW Bosch Rexroth Indramat
MPN: R911396900
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The Bosch Rexroth Indramat HCS01.1E-W0018-A-03-B-ET-EC-EP-DA-NN-FW is an HCS IndraDrive Controller with a device peak current of 18 Amps and an IP20 rating. It has MultiEthernet communication, supports encoder interfaces like IndraDyn Hiperface and EnDat 2.1/2.2, and uses air cooling through an integrated blower. The controller operates with a main voltage of 3 x AC 200 to 500 Volts and features a BASIC control section design.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The HCS01.1E-W0018-A-03-B-ET-EC-EP-DA-NN-FW is a drive controller produced by Bosch Rexroth Indramat for the HCS IndraDrive Controllers series. It converts incoming three-phase power and performs torque and position control for servo or spindle axes in automated machinery. The unit provides the electrical interface between the plant mains and the motor, allowing precise motion sequences in production equipment. This arrangement supports controlled acceleration, speed regulation, and positioning within a compact cabinet-mounted drive system.
Network communication is handled through a MultiEthernet port, so the controller can connect to EtherCAT, EtherNet/IP, PROFINET, or SERCOS networks without additional hardware. The control section is supplied in the BASIC configuration, which provides standard motion functions. A protection level of IP20 requires installation inside a cabinet, and cooling is provided by internal airflow from an integrated blower. During operation, the power stage can supply a peak current of 18 A to the attached motor while accepting utility power at 3 × AC 200–500 V with a tolerance of ±10 percent. This input range allows the same unit to operate across multiple regional voltage systems.
The drive is design version 1 and matches the mechanical footprint of the HCS01 line. Feedback is connected through an Encoder IndraDyn Hiperface/EnDat 2.1/2.2 interface, allowing the drive to process absolute position data directly from supported motors. DC-bus management uses infeeding and fed operation, so the inverter can draw energy from the supply section and return regenerated power to the common link. The power section must be paired with the designated control section to complete the axis controller, and this layout supports compact integration in enclosed automation cabinets.
Frequently Asked Questions about HCS01.1E-W0018-A-03-B-ET-EC-EP-DA-NN-FW:
Q: What type of communication interface is available on the HCS01.1E-W0018-A-03-B-ET-EC-EP-DA-NN-FW drive controller?
A: The HCS01.1E-W0018-A-03-B-ET-EC-EP-DA-NN-FW is equipped with a MultiEthernet communication interface for flexible connectivity.
Q: How is the HCS01.1E-W0018-A-03-B-ET-EC-EP-DA-NN-FW cooled during operation?
A: This drive controller uses an internal air cooling system with an integrated blower for temperature management.
Q: What is the peak current rating of the HCS01.1E-W0018-A-03-B-ET-EC-EP-DA-NN-FW drive controller?
A: The device supports a peak current of 18 A, allowing for high power output during demanding operations.
Q: What mains voltage range does the HCS01.1E-W0018-A-03-B-ET-EC-EP-DA-NN-FW support?
A: It operates with a mains voltage range of 3 x AC 200 to 500 V with a ±10% tolerance.
Q: What types of encoder interfaces are supported by this drive controller?
A: The HCS01.1E-W0018-A-03-B-ET-EC-EP-DA-NN-FW offers an encoder interface compatible with IndraDyn Hiperface and EnDat 2.1/2.2.