4.95 based on 202 reviews

🙶 Excellent to work with and they stand behind their work. I would highly recommend them. 🙷

HCS01.1E-W0018-A-03-B-ET-EC-EM-S5-NN-FW Bosch Rexroth Indramat

MPN: R911383027

No Tariffs On US Orders
  • Rated 4.4 (49 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
Ask for Availability

Preparing your secure checkout page...

The Bosch Rexroth Indramat HCS01.1E-W0018-A-03-B-ET-EC-EM-S5-NN-FW is a drive controller in the HCS IndraDrive Controllers series. It supports MultiEthernet communication and features air cooling through an integrated blower. The device offers a peak current of 18 Amps and operates with a mains voltage range of 3 x AC 200 to 500 Volts with IP20 rating.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The HCS01.1E-W0018-A-03-B-ET-EC-EM-S5-NN-FW is a drive controller manufactured by Bosch Rexroth Indramat for the HCS IndraDrive Controllers series. It combines power electronics and motion control in one module to manage a single servo axis in automated packaging, assembly, or handling equipment. By regulating current, speed, and position while exchanging data with a PLC, the unit provides the closed-loop control needed for precise industrial motion.

Coded as design version 1 in the HCS01 line, the controller links to supervisory systems through a MultiEthernet interface, allowing EtherNet/IP, PROFINET, or EtherCAT connectivity without add-on cards. It is delivered with a BASIC control section, so standard positioning tasks are supported while advanced safety features remain optional. The power stage accepts a three-phase mains supply of 3 x AC 200...500 V ±10%, making it compatible with common plant voltage ranges. Short-term motor demand is supported up to a peak of 18 A, allowing brief increases in torque when the application requires it. An enclosure rating of IP20 provides finger protection but requires installation inside a ventilated cabinet. No additional design options are declared for this version.

Heat is removed by internal air cooling through an integrated blower, so the drive moves cabinet air across the heat sink without external ducting. Interface 1 supports IndraDyn Hiperface/EnDat 2.1/2.2 encoder feedback for absolute motor position data. Interface 2 provides encoder emulation for downstream devices that require incremental pulse signals. The power module is rated for infeed and fed operation, meaning it can both supply and absorb energy on a shared DC bus. This arrangement supports integration with absolute-feedback motors while also serving external equipment that relies on emulated encoder signals.

Communication Interface
MultiEthernet
Control Section Design Type
BASIC
Cooling Method
Air, internal (through integrated blower)
Design Version
1
Device Peak Current
18 A
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Interface 2 Type
Encoder emulation
IP Rating
IP20
Line Series
HCS01
Mains Voltage
3 x AC 200...500 V ±10%
Other Design Features
None
Pairing Note
Paired with Control Section Design 'BASIC' (B)
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
  • HCS011EW0018A03BETECEMS5NNFW
  • HCS01 1E W0018 A 03 B ET EC EM S5 NN FW
  • hcs01.1e-w0018-a-03-a-cc-ec-cn-l3-nn-fw
  • HCS1.1E-W0018-A-03-B-ET-EC-EM-S5-NN-FW

Frequently Asked Questions about HCS01.1E-W0018-A-03-B-ET-EC-EM-S5-NN-FW:

Q: What communication interface does the HCS01.1E-W0018-A-03-B-ET-EC-EM-S5-NN-FW controller use?

A: The HCS01.1E-W0018-A-03-B-ET-EC-EM-S5-NN-FW controller utilizes a MultiEthernet communication interface for industrial network compatibility.

Q: What cooling method is used in the HCS01.1E-W0018-A-03-B-ET-EC-EM-S5-NN-FW?

A: This controller features an internal air cooling method with an integrated blower.

Q: What is the peak current rating of the HCS01.1E-W0018-A-03-B-ET-EC-EM-S5-NN-FW controller?

A: The device supports a peak current of 18 A, making it suitable for medium power applications.

Q: What types of encoder interfaces are available on this drive controller?

A: It offers an encoder interface supporting IndraDyn, Hiperface, and EnDat 2.1/2.2 for feedback devices.

Q: What mains voltage does the HCS01.1E-W0018-A-03-B-ET-EC-EM-S5-NN-FW require?

A: The main voltage supply for this model is 3-phase AC, ranging from 200 to 500 V ±10%.


Internal Product Review

  • ‘‘The HCS01.1E-W0018-A-03-B-ET-EC-EM-S5-NN-FW is an HCS drive controller with MultiEthernet communication and a BASIC control section. Internal blower cooling supports stable thermal performance, and the 18 A peak current gives the unit strong dynamic response. The 3 x AC 200...500 V input range makes this controller a very capable choice for demanding industrial drive applications.’’